Key result
Evolut valves show ~4-degree lower angular plane shift than Sapien valves in TAVR.
Why the study?
Optimal valve positioning is essential for TAVR success, yet the relationship between the native aortic annulus plane and the final implanted valve orientation remains poorly understood. This study quantified the angular difference between the planned and actual planes of implantation stratified by valve type and examined its predictors and clinical associations.
Does valve type (Medtronic Evolut vs. Edwards Sapien) and patient anatomy affect the angular plane difference between planned and actual valve implantation in transfemoral TAVR patients, and does plane shift predict post-TAVR adverse outcomes?
Cohort (n=36)
No
Does valve type (Medtronic Evolut vs. Edwards Sapien) and patient anatomy affect the angular plane difference between planned and actual valve implantation in transfemoral TAVR patients, and does plane shift predict post-TAVR adverse outcomes?
An angular plane shift between planned and actual valve implantation occurs in all transfemoral TAVR patients, varies by valve type, and significantly predicts moderate post-TAVR aortic insufficiency.
Plane shift may increase post-TAVR aortic insufficiency risk; leaves open whether valve selection optimizes implantation accuracy.
Introduction Optimal positioning of a transcatheter aortic valve is essential for procedural success and long-term function in TAVR. The S-curve, derived from pre-procedural imaging, guides C-arm angulation to achieve alignment with the aortic annulus and ensure accurate valve deployment. Proper alignment minimizes complications such as paravalvular leak, coronary obstruction, and conduction disturbances. Despite its clinical relevance, the relationship between native aortic annulus plane and final implanted valve orientation remains poorly understood. Variability in anatomy, valve type, and deployment dynamics may contribute to discrepancies between intended and actual valve positioning. Aim This study aimed to quantify the plane difference between the planned plane of implantation with the actual plane of implantation, stratified by valve type. Secondary analyses examined predictors of greater misalignment and its association with post-TAVR outcomes, including paravalvular leak, implantation depth, and pacemaker implantation. Methods This retrospective single-center cohort included 36 transfemoral TAVR patients who underwent pre- and post-procedural CT for S-curve assessment of native and implanted valves. The angular difference between pre- and post-procedure valve planes were calculated for each patient. Linear and logistic regression models with stepwise selection identified anatomical, echocardiographic, and procedural predictors of plane shift, post-implantation aortic insufficiency, and pacemaker implantation. Results Among 36 TAVR patients (median age 76.2 years, 27.8% male), plane difference was demonstrated in all patients 8.23 degrees median (5.2,12.62 IQR). Medtronic Evolut valves showed lower plane shift than the Edwards Sapien valves (Estimate = − 4.37, 95% CI [–8.55 to − 0.18], p = 0.042). Plane shift predicted moderate post-TAVR aortic insufficiency (OR = 1.38, 95% CI [1.04–1.83], p = 0.026. Conclusion Plane difference between planned and actual implantation plane were demonstrated in all patients. Anatomical and procedural factors influence valve alignment, underscoring the need for optimized imaging and deployment strategies to minimize post-TAVR adverse outcomes. Clinical trial number Not applicable.
No takes yet. Share an insight, caveat, or question.
Erez et al. (2026) conducted a cohort in Severe aortic stenosis undergoing transfemoral transcatheter aortic valve replacement (TAVR) (n=36). Medtronic Evolut self-expanding transcatheter aortic valve vs. Edwards Sapien S3 balloon-expandable transcatheter aortic valve was evaluated on Angular plane shift between planned native annular plane and actual implanted valve plane (degrees) (MD -4.37 degrees, 95% CI -8.55 to -0.18, p=0.042). Medtronic Evolut valves had lower angular plane shift than Edwards Sapien valves (MD -4.37 degrees, 95% CI -8.55 to -0.18, p=0.042), and greater plane shift predicted moderate aortic insufficiency.