Key result
Transcatheter mitral ViV/ViR yields lower 30-day device success than redo-MVR, with comparable mortality.
Why the study?
Transcatheter mitral valve-in-valve (ViV) and valve-in-ring (ViR) procedures have emerged as alternatives for failed mitral bioprostheses or ring annuloplasty, while redo surgical mitral valve replacement (redo-MVR) remains standard therapy despite perceived higher procedural risk. This study aimed to descriptively compare short- and long-term outcomes of ViV/ViR and redo-MVR.
Does transcatheter mitral valve-in-valve or valve-in-ring (ViV/ViR) improve 30-day mortality and MVARC-defined device success compared to redo surgical mitral valve replacement in patients older than 60 years with failed mitral valve bioprostheses or repairs?
Cohort (n=30)
No
Does transcatheter mitral valve-in-valve or valve-in-ring (ViV/ViR) improve 30-day mortality and MVARC-defined device success compared to redo surgical mitral valve replacement in patients older than 60 years with failed mitral valve bioprostheses or repairs?
Answers are grounded in this paper and cite their sources.
In a small retrospective cohort of patients over 60 with failed mitral bioprostheses or repairs, both transcatheter ViV/ViR and redo surgical MVR showed low 30-day mortality, though redo-MVR achieved higher 30-day device success largely due to lower postoperative gradients.
Background/Objectives: Transcatheter mitral valve-in-valve (ViV) and valve-in-ring (ViR) procedures have emerged as alternative treatment options for failed mitral valves following prior bioprosthetic replacement or ring annuloplasty. However, redo surgical mitral valve replacement (redo-MVR) remains the standard therapy despite its perceived higher procedural risk. This study aimed to descriptively compare short- and long-term outcomes of ViV/ViR and redo-MVR. Methods: We retrospectively included patients older than 60 years who underwent treatment of failed mitral valve bioprostheses or repairs between 2000 and 2022 (n = 30; ViV/ViR cohort: 2008–2022). Patients treated with ViV/ViR (n = 15) were compared with those undergoing redo-MVR (n = 15). Endpoints were reported according to Mitral Valve Academic Research Consortium (MVARC) criteria. Technical, device, and procedural success were defined according to the MVARC criteria and applied identically to both groups. Owing to the small sample size and substantial baseline differences, this study is descriptive and hypothesis-generating. Results: Patients in the ViV/ViR group were significantly older than redo-MVR patients (76.9 ± 5.8 vs. 68.0 ± 8.4 years, p < 0.001). EuroSCORE II did not differ significantly between groups. Thirty-day mortality was comparable, with one death in the ViV/ViR group and none after redo-MVR (6.7% vs. 0%, p = 1.00). Device success at 30 days was significantly higher after redo-MVR compared with ViV/ViR (86.7% vs. 40.0%, p = 0.02). Neurological events were rare and similar between groups. Degenerated bioprostheses were more frequent in the ViV/ViR group (86.6%), whereas prior annuloplasty ring implantation predominated in redo-MVR patients (80.0%, p < 0.01). Pre-procedural and discharge mitral valve gradients were higher in ViV/ViR patients. Implanted valve size was smaller in the ViV/ViR cohort (28.2 ± 1.4 vs. 29.5 ± 1.8 mm, p = 0.03). Conclusions: In this small, retrospective, single-center cohort with substantial baseline differences (e.g., age), 30-day mortality was low in both groups. Device success was higher after redo-MVR, mainly because of higher postoperative gradients after ViV/ViR. These findings are descriptive and hypothesis-generating and do not constitute evidence of comparative treatment effectiveness. Both approaches may be considered complementary options guided by a multidisciplinary heart team.
No takes yet. Share an insight, caveat, or question.
Kruse et al. (2026) conducted a cohort in Failed mitral valve bioprostheses or repairs (n=30). Transcatheter mitral valve-in-valve (ViV) or valve-in-ring (ViR) vs. Redo surgical mitral valve replacement (redo-MVR) was evaluated on 30-day device success (MVARC criteria) (p=0.02). Transcatheter mitral ViV/ViR had lower 30-day device success than redo-MVR (40.0% vs 86.7%, p=0.02) and comparable 30-day mortality (6.7% vs 0%, p=1.00).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: