Key result
Everolimus-eluting stents cut 10-year composite events ~19% vs. bare-metal stents in STEMI.
Why the study?
Extended long-term outcomes data for a durable-polymer everolimus-eluting stent in patients with STEMI were unknown.
Does a durable-polymer everolimus-eluting stent reduce the patient-oriented composite endpoint of all-cause death, any myocardial infarction, or any revascularization at 10 years compared to bare-metal stents in patients with STEMI requiring primary percutaneous coronary intervention?
RCT (n=1,498)
1:1 ratio
Does a durable-polymer everolimus-eluting stent reduce the patient-oriented composite endpoint of all-cause death, any myocardial infarction, or any revascularization at 10 years compared to bare-metal stents in patients with STEMI requiring primary percutaneous coronary intervention?
At 10-year follow-up, durable-polymer everolimus-eluting stents maintained superior efficacy over bare-metal stents in reducing combined patient- and device-oriented composite endpoints in STEMI patients, driven primarily by lower target lesion revascularization, with low and comparable rates of late device failure between 5 and 10 years.
Supports EES over BMS for 10-year POCE/DOCE in STEMI PCI; confirms early TLR reduction sustains superiority without late divergence.
BACKGROUND Outcomes data for a durable-polymer everolimus-eluting stent (EES) at extended long-term follow-up in patients with ST-segment elevation myocardial infarction (STEMI) are unknown. OBJECTIVES The aim of this study was to assess the 10-year outcomes of patients enrolled in the EXAMINATION (A Clinical Evaluation of Everolimus Eluting Coronary Stents in the Treatment of Patients With ST-Segment Elevation Myocardial Infarction) trial. METHODS The EXAMINATION-EXTEND (10-Years Follow-Up of the EXAMINATION Trial) study is an investigator-driven 10-year follow-up of the EXAMINATION trial, which randomly assigned 1,498 patients with STEMI in a 1:1 ratio to receive either EES (n = 751) or bare-metal stents (n = 747). The primary endpoint was a patient-oriented composite endpoint of all-cause death, any myocardial infarction, or any revascularization. Secondary endpoints included a device-oriented composite endpoint of cardiac death, target vessel myocardial infarction, or target lesion revascularization; the individual components of the combined endpoints; and stent thrombosis. RESULTS Complete 10-year clinical follow-up was obtained in 94.5% of the EES group and 95.9% of the bare-metal stent group. Rates of the patient-oriented composite endpoint and device-oriented composite endpoint were significantly reduced in the EES group (32.4% vs. 38.0% [hazard ratio: 0.81; 95% confidence interval: 0.68 to 0.96; p = 0.013] and 13.6% vs. 18.4% [hazard ratio: 0.72; 95% confidence interval: 0.55 to 0.93; p = 0.012], respectively), driven mainly by target lesion revascularization (5.7% vs. 8.8%; p = 0.018). The rate of definite stent thrombosis was similar in both groups (2.2% vs. 2.5%; p = 0.590). No differences were found between the groups in terms of target lesion revascularization (1.4% vs. 1.3%; p = 0.963) and definite or probable stent thrombosis (0.6% vs. 0.4%; p = 0.703) between 5 and 10 years. CONCLUSIONS At 10-year follow-up, EES demonstrated confirmed superiority in combined patient- and device-oriented composite endpoints compared with bare-metal stents in patients with STEMI requiring primary percutaneous coronary intervention. Between 5- and 10-year follow-up, a low incidence of adverse cardiovascular events related to device failure was found in both groups. (10-Years Follow-Up of the EXAMINATION Trial; NCT04462315).
No takes yet. Share an insight, caveat, or question.
Brugaletta et al. (2021) conducted an RCT in ST-segment elevation myocardial infarction (STEMI) (n=1,498). Durable-polymer everolimus-eluting stent (EES) vs. Bare-metal stents (BMS) was evaluated on Patient-oriented composite endpoint of all-cause death, any myocardial infarction, or any revascularization (HR 0.81, 95% CI 0.68-0.96, p=0.013). Everolimus-eluting stents were superior to bare-metal stents in reducing death, MI, or revascularization at 10 years in STEMI (32.4% vs 38.0%; HR 0.81; 95% CI 0.68-0.96; p=0.013).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: