Transferring interface forces between a steel hollow section and the infilled concrete in concrete-filled steel tubular (CFST) structures usually needs careful consideration during design. This work proposed using diagonal-binding-plate shear connectors to enhance the interface shear resistance of CFST columns. Push-out tests were conducted, including a total of 13 CFST specimens with diagonal-binding-plate shear connectors along with two reference specimens. The test variables included the width-to-thickness ratio of steel tube, cross-sectional dimensions, concrete strength, and details of diagonal-binding-plate shear connectors (e.g., width, thickness, longitudinal length, and opening details in shear connectors). The research results demonstrated the interface shear resistance was effectively improved by diagonal-binding-plate shear connectors, with a maximum increase of approximately seven times compared with specimens without shear connectors. Furthermore, a finite-element model based on the Dynamic Implicit solver was developed, and parametric analysis was conducted. The load-transfer mechanism based on confinement effect of steel tube and local compression of concrete was analyzed in detail. Corresponding formulas for predicting the load capacity of diagonal-binding-plate shear connectors under local compression failure of concrete and design recommendations were proposed.
No takes yet. Share an insight, caveat, or question.
Gan et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: