Background and aims: Adenoma detection rate (ADR) is the principal quality indicator of colonoscopy and is inversely associated with post-colonoscopy colorectal cancer (PCCRC). Artificial intelligence (AI)-based computer-aided detection (CADe) systems built on deep convolutional neural networks provide real-time visual alerts for suspected polyps. We aimed to comprehensively synthesise randomised and primary non-randomised evidence published in the last 15 years on the efficacy, effectiveness and diagnostic performance of CADe-assisted colonoscopy for colorectal polyp detection. Methods: The study strictly adhered to the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) 2020 guidelines. Eligible designs were randomised controlled trials (RCTs), comparative studies, cohorts and case series; systematic reviews and meta-analyses were excluded from the evidence base and considered only in the discussion. Risk of bias was assessed with RoB 2, ROBINS-I and the JBI case-series checklist. Random-effects meta-analyses used restricted maximum-likelihood heterogeneity estimation with Hartung–Knapp–Sidik–Jonkman (HKSJ) confidence intervals and 95% prediction intervals (PI). Certainty of evidence was rated with GRADE. Results: Sixty-three studies were included (43 RCTs, 12 non-randomised comparative studies and 8 case/validation series; more than 79,000 colonoscopies). In 34 parallel-group RCTs (n = 34,010), CADe increased ADR from 41.4% to 47.4% (risk ratio [RR] 1.16 (95% CI 1.11–1.22); I² = 66%; 95% PI 0.94–1.43; low certainty). CADe halved the adenoma miss rate in tandem RCTs (RR 0.49 (95% CI 0.32–0.75); moderate certainty), increased polyp detection (RR 1.21 (95% CI 1.08–1.35)) and adenomas per colonoscopy (mean difference 0.27 (95% CI 0.15–0.38)), but did not increase detection of advanced adenoma/advanced neoplasia (RR 1.04 (95% CI 0.95–1.14)) or, with statistical certainty, serrated lesions (RR 1.48 (95% CI 0.80–2.73)). The relative benefit declined with higher control-arm ADR (meta-regression P < 0.001; R² = 67%), from RR 1.45 when baseline ADR was below 30% to RR 1.08 when it was 45% or higher, and attenuated in more recent and FIT-positive trials. In non-randomised real-world cohorts the pooled effect was smaller and non-significant (odds ratio 1.20 (95% CI 0.98–1.46); very low certainty). Small-study effects were present (Egger P = 0.004), although the trim-and-fill-adjusted estimate remained favourable (RR 1.11). Stand-alone validation series reported per-lesion or per-image sensitivities of approximately 87–100%. Conclusions: CADe-assisted colonoscopy consistently increases the detection of predominantly diminutive, non-advanced adenomas and reduces miss rates, with the greatest gains among lower-performing endoscopists. Its effect on advanced neoplasia, serrated lesions and, ultimately, PCCRC incidence remains unproven, and benefits are attenuated in high-performing and real-world settings. Implementation should be targeted, monitored and coupled with strategies that mitigate automation bias and deskilling.
No takes yet. Share an insight, caveat, or question.
Alhabib et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: