Key result
Exercise-induced MTWA predicts ~3.8-fold higher risk of ventricular tachyarrhythmic events.
Why the study?
Previous studies evaluating microvolt T-wave alternans (MTWA) as a predictor of ventricular tachyarrhythmic events were limited by small sample sizes and disparate populations.
Does exercise-induced microvolt T-wave alternans testing predict ventricular tachyarrhythmic events across a wide variety of patient populations?
Meta-Analysis (n=2,608)
Yes
Does exercise-induced microvolt T-wave alternans testing predict ventricular tachyarrhythmic events across a wide variety of patient populations?
Exercise-induced microvolt T-wave alternans testing has a high negative predictive value (97.2%) and significantly predicts ventricular tachyarrhythmic events (RR 3.77), though its positive predictive value varies substantially across patient populations.
MTWA may aid ventricular tachyarrhythmia risk stratification; leaves open need for randomized validation before clinical adoption.
Objectives The objective of this study was to perform a meta-analysis of the predictive value of microvolt T-wave alternans (MTWA) testing for arrhythmic events in a wide variety of populations. Background Previous studies describing the use of MTWA as a predictor of ventricular tachyarrhythmic events have been limited by small sample sizes and disparate populations. Methods Prospective studies of the predictive value of exercise-induced MTWA published between January 1990 and December 2004 were retrieved. Data from each article were abstracted independently by two authors using a standardized protocol. Summary estimates of the predictive value of MTWA were made using a random-effects model. Results Data were accumulated from 19 studies (2,608 subjects) across a wide range of populations. Overall, the positive predictive value of MTWA for arrhythmic events was 19.3% at an average of 21 months' follow-up (95% confidence interval [CI] 17.7% to 21.0%), the negative predictive value was 97.2% (95% CI 96.5% to 97.9%), and the univariate relative risk of an arrhythmic event was 3.77 (95% CI 2.39 to 5.95). There was no difference in predictive value between ischemic and nonischemic heart failure subgroups. The positive predictive value varied depending on the population of patients studied (p < 0.0001). Conclusions Microvolt T-wave alternans testing has significant value for the prediction of ventricular tachyarrhythmic events; however, there are significant limitations to its use. The predictive value of MTWA varies significantly depending on the population studied. Careful standardization is needed for what constitutes abnormal MTWA. The incremental prognostic value of MTWA when used with other methods of risk stratification is unclear.
No takes yet. Share an insight, caveat, or question.
Gehi et al. (2005) conducted a meta-analysis in Ventricular tachyarrhythmic events (n=2,608). Exercise-induced microvolt T-wave alternans (MTWA) testing vs. Normal/negative MTWA was evaluated on Ventricular tachyarrhythmic events (RR 3.77, 95% CI 2.39-5.95). Exercise-induced microvolt T-wave alternans predicted ventricular tachyarrhythmic events with a relative risk of 3.77 (95% CI 2.39-5.95), a PPV of 19.3%, and an NPV of 97.2%.