Key result
Plug-anchored coil embolization successfully seals a high-flow aortic pseudoaneurysm after TAVR with BASILICA.
Why the study?
Coil deployment alone in a paravalvular aortic pseudoaneurysm after TAVR with BASILICA can cause frequent coil prolapse into the left ventricle given the high-flow state, prompting description of plug-anchored coil embolization using an Amplatzer Vascular Plug II.
Case Report (n=1)
Using a vascular plug device as a stabilizing anchor facilitates controlled coil deployment and prevents coil prolapse during the embolization of large, high-flow paravalvular aortic pseudoaneurysms post-TAVR.
Captured external expert commentary on this paper, strongest first. Original sources are linked where available.
““During coil embolization of a large, high flow pseudoaneurysm, a vascular plug device can be used as a stabilizing anchor and scaffold to facilitate controlled coil deployment and allow packing of the pseudoaneurysm.””
May facilitate controlled coil embolization in high-flow post-TAVR pseudoaneurysms; single-case experience leaves open reproducibility and durability.
Objective We present a case of aortic pseudoaneurysm after transcatheter aortic valve replacement with BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction), which was tackled with coil embolization with an Amplatzer Vascular Plug II (AVP) acting as an anchor for entanglement. Key Steps The steps were as follows. 1) Obtain bilateral common femoral artery access. 2) Advance 8-F JL 4.5 guide catheter through an Agilis large-curl steerable catheter to engage the aortic pseudoaneurysm adjacent to the left aortic cusp. 3) Deliver the AVP to the pseudoaneurysm while leaving it attached to the delivery cable. 4) Advance an EBU-4.5 6-F guide catheter, then an Excelsior SL-10 microcatheter, to deploy coils into the pseudoaneurysm around the AVP, which acts as an anchor. 5) Deploy multiple coils until resistance is met. 6) Final release of the AVP anchor after sealing the pseudoaneurysm. Potential Pitfalls Coil deployment alone can cause frequent coil prolapse into left ventricle given the high flow state of the pseudoaneurysm. Release of AVP before adequate coil packing of the pseudoaneurysm may result in AVP embolization or pseudoaneurysm rupture. Take-Home Message During coil embolization of a large, high-flow pseudoaneurysm, a vascular plug device can be used as a stabilizing anchor to facilitate controlled coil deployment.
No takes yet. Share an insight, caveat, or question.
Chan et al. (2026) conducted a case report in Paravalvular aortic pseudoaneurysm after transcatheter aortic valve replacement (TAVR) with BASILICA (n=1). Coil embolization with an Amplatzer Vascular Plug II (AVP) anchor was evaluated on Sealing of the aortic pseudoaneurysm. Coil embolization using an Amplatzer Vascular Plug II as a stabilizing anchor successfully sealed a high-flow aortic pseudoaneurysm after TAVR with BASILICA.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: