This study presents, to our knowledge, the first dosimetric evaluation of occupational radiation exposure among orthopedic teams using C-arm fluoroscopy in Palestine. Thermoluminescence dosemeters (LiF:Mg,Ti, TLD-100) measured Hₚ(10) and Hₚ(0.07) at five anatomical sites on one surgeon during six procedures over 32 days: unshielded upper arms and shielded thyroid, chest, and gonads. The highest measured personal dose equivalent, Hₚ(10), was 0.21 mSv at the unshielded right upper arm (30-day normalized value: 0.19 mSv; 11.7% of the monthly reference value derived from the International Commission on Radiological Protection annual occupational effective-dose limit). Although shielding reduced torso exposure, safety compliance was poor: 37% of staff consistently used lead aprons, 22.2% used thyroid shields, and 13.3% used dosemeters. These findings identify systemic gaps requiring enforced protection measures, routine monitoring, and staff education.
No takes yet. Share an insight, caveat, or question.
Zalloum et al. (2026) studied this question.