Key result
AI-guided SPOT-DIXON achieves ~84% segmentation accuracy for rapid, simultaneous scar and fat quantification.
Why the study?
While black-blood late gadolinium enhancement improves myocardial scar conspicuity in cardiomyopathies, fat remains hyperintense and may confound interpretation, motivating the development of a technique for simultaneous, co-registered quantification of scar and fat.
Does AI-guided SPOT-DIXON improve simultaneous quantification and segmentation of myocardial scar and fat compared to reference LGE sequences and manual delineation in patients referred for cardiac MRI?
Cohort (n=36)
Does AI-guided SPOT-DIXON improve simultaneous quantification and segmentation of myocardial scar and fat compared to reference LGE sequences and manual delineation in patients referred for cardiac MRI?
Answers are grounded in this paper and cite their sources.
AI-guided SPOT-DIXON enables rapid, simultaneous, and co-registered quantification of myocardial scar and fat within a single cardiac MRI acquisition, introducing novel markers of fibrofatty remodeling.
Aims Characterization of myocardial scar and fat is clinically important for diagnosis, risk stratification, and procedural planning in cardiomyopathies. While black-blood late gadolinium enhancement (LGE) improves scar conspicuity, fat remains hyperintense and may confound interpretation. We aimed to develop and evaluate SPOT-DIXON, a dual bright- and black-blood LGE sequence with Dixon water-fat separation and artificial intelligence (AI)-guided analysis, enabling simultaneous and co-registered quantification of myocardial scar and intra- and extra-cardiac fat. Methods SPOT-DIXON alternates bright- and black-blood LGE preparations on consecutive heartbeats while acquiring dual-echo data for Dixon water-fat separation. Simulations, phantom experiments, and validations in a prospective cohort of 36 patients referred for cardiac MRI were performed. An AI model automatically segmented the left ventricular (LV) wall on bright-blood water images, with contours propagation to scar and fat images. Results Simulations and phantoms confirmed preserved bright- and black-blood contrast and accurate water-fat separation. In patients, AI-based LV wall segmentation showed excellent agreement with manual delineation (global DICE=84.4 ± 4.0%). SPOT-DIXON yielded higher scar volume, burden, and transmurality measurements than reference sequences, while LV wall volume was similar between sequences. Novel quantitative metrics, including intramyocardial fat burden expressed relative to scar mass, were feasible only with SPOT-DIXON. Acquisition times were comparable across sequences (5min55s ± 2min17 s), while AI-based analysis substantially reduced post-processing time to 2.1 ± 0.7 seconds. Conclusion AI-guided SPOT-DIXON enables simultaneous, co-registered assessment of myocardial scar and fat within a single LGE acquisition. This approach overcomes key limitations of current workflows and introduces novel quantitative markers of fibrofatty remodelling with potential clinical relevance in cardiomyopathies.
No takes yet. Share an insight, caveat, or question.
Narceau et al. (2026) conducted a cohort in Cardiomyopathies / referred for cardiac MRI (n=36). AI-guided SPOT-DIXON (dual bright- and black-blood LGE with Dixon water-fat separation) vs. Manual delineation and reference LGE sequences was evaluated on Agreement of AI-based left ventricular wall segmentation with manual delineation (global DICE) and simultaneous quantification of myocardial scar and fat. AI-guided SPOT-DIXON achieved 84.4% DICE agreement with manual LV segmentation in 2.1s post-processing, enabling simultaneous myocardial scar and fat quantification.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: