Guided wave testing (GWT) is governed by standards that define it as a method categorically distinct from conventional ultrasonic testing (UT). This paper challenges that classification on physical grounds. Extending the acoustic impedance relationship from point-contact UT, Z = ρv, to the guided wave case, Z = Aρv, where A is the cross-sectional area of the pipe wall, shows that GWT is ultrasonic testing at low frequency with area-weighted acoustic impedance. The consequences are examined through two results that follow directly from the unification: controlled plate measurements confirming the quarter-wavelength resonance condition up to 250 kHz, and a derived minimum operating frequency of 64 kHz for reliable detection of early-stage corrosion under insulation, with 90 and 128 kHz identified as the preferred frequencies. Six systematic gaps in current standards are identified against this framework, and specific revisions are proposed.