BACKGROUND: A 3-dimensional (3D) understanding of device positioning is essential for successful percutaneous coronary intervention. We developed a novel method to visualize the 3D relationship between dual guiding catheters from orthogonal fluoroscopic images using 3D computer-aided design software. CASE SUMMARY: We present 4 complex percutaneous coronary intervention cases where the right coronary artery catheter was initially positioned posterior to the left coronary artery catheter. This caused instability or disengagement; however, repositioning the right coronary artery catheter anteriorly improved coaxial alignment and achieved system stability, enabling procedural success. DISCUSSION: Intentionally inverting this anterior-posterior relationship-either by exchanging the catheter shape or via manual re-engagement manipulation-successfully optimized coaxial alignment and system stability, allowing successful lesion completion. TAKE-HOME MESSAGES: The 3D spatial relationship of dual guiding catheters should be recognized from 2 orthogonal fluoroscopic images. Furthermore, strategic configuration inversion should be considered when necessary to optimize catheter stability and procedural success.
No takes yet. Share an insight, caveat, or question.
Yokoi et al. (2026) studied this question.