Answers are grounded in this paper and cite their sources.
Alveolar ridge resorption following tooth loss impedes prosthetically driven dental implant placement. Although autogenous bone blocks remain the gold standard, donor-site morbidity limits their use. Autogenous dentin blocks (ADB) and synthetic poly(lactic-co-glycolic acid) combined with β-tricalcium phosphate (PLGA/β-TCP) scaffolds have been investigated in protocols avoiding separate autogenous block harvesting. This study evaluated 6-month radiographic augmented hard-tissue volume and horizontal ridge width changes achieved with PLGA/β-TCP scaffolds versus ADBs within standardized multi-material augmentation protocols. Sixty-five augmented sites in 41 patients were retrospectively evaluated (PLGA/β-TCP: 32 sites in 22 patients; ADB: 33 sites in 19 patients). Both protocols utilized screw fixation, a 1:1 mixture of autogenous bone scrapings and bovine xenograft, and titanium-prepared platelet-rich fibrin membranes. Preoperative and 6-month postoperative CBCT datasets were aligned using stable anatomical landmarks. Horizontal ridge widths (at 3, 5 and 7 mm depths) and 3D augmented hard-tissue volumes were evaluated using Romexis and ITK-SNAP software. Primary horizontal outcomes were analyzed using baseline-adjusted linear mixed-effects models (LMM), specifying random intercepts for patients and sites nested within patients. A patient-random-intercept model was used for volumetric analysis. Measurement repeatability was determined using the intraclass correlation coefficient (ICC). Intra-observer reliability was high (ICC:0.86–0.93). In primary LMM analyses, adjusted PLGA-minus-ADB differences in 6-month horizontal width were − 0.25 mm at 3 mm (95% CI: −0.71 to 0.22; p = 0.297), − 0.28 mm at 5 mm (95% CI: −0.74 to 0.18; p = 0.223), and − 0.35 mm at 7 mm (95% CI: −0.81 to 0.11; p = 0.135). The treatment-by-depth interaction was not statistically significant ( p = 0.875). For radiographic augmented hard-tissue volume, the adjusted difference was − 34.47 mm³ (95% CI: −288.10 to 219.15; p = 0.784). Seven patients experienced localized complications (5/22 PLGA vs. 2/19 ADB; Fisher’s exact test, p = 0.419), with zero graft loss. Both multimaterial protocols demonstrated descriptive increases in horizontal ridge dimensions and radiographic augmented hard-tissue volume at 6 months. In baseline-adjusted hierarchical models, no statistically significant between-group differences were detected. Both techniques successfully avoided harvesting a separate intraoral autogenous bone block; however, the confidence intervals do not demonstrate clinical equivalence or interchangeability, and long-term peri-implant stability warrants prospective investigation.
No takes yet. Share an insight, caveat, or question.
Dağtekin et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: