Electrical single-line diagrams contain symbols with substantial scale variation, thin-line structures, hollow contours, and dense layouts, posing challenges for automatic symbol detection. This study proposes SAFE-YOLO, a YOLOv11s-based detector that integrates local structure modeling, spatial–channel interaction, and multi-scale feature fusion. The structure–frequency-enhanced C3k2 module (C3k2_SF) combines adaptive sampling with frequency-aware channel recalibration. Spatial and channel-wise interactive attention (SICA) introduces bidirectional modulation between spatial and channel branches, while an adopted parallel asymptotic feature fusion network (PAFFN) supports cross-scale feature aggregation and recalibration. Experiments on a dataset of 543 electrical single-line diagrams covering 24 symbol categories showed that SAFE-YOLO achieved an mAP@0.5 of 93.6 ± 0.2%, compared with 88.6 ± 0.1% for YOLOv11s. Measured throughput decreased from 117.6 to 74.1 images/s, while mean latency increased from 8.4 to 13.6 ms per image. These results indicate improved detection accuracy under the adopted evaluation protocol, accompanied by increased inference time. SAFE-YOLO provides a task-oriented option for offline electrical-drawing processing when the additional processing cost is acceptable.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: