Key result
Resonance frequency breathing shows poor 1-week test-retest stability, shifting over 0.5 breaths/min in ~25% of individuals.
Why the study?
Resonance frequency is used to guide optimal breathing rate for cardiovascular and autonomic benefits, but evidence on its stability over time is scarce and previous research reported poor 1-week test-retest reliability in a small sample.
Observational (n=51)
Individual resonance frequency breathing rate shows low test-retest stability over a 1-week period, challenging the clinical assumption that a single assessment is sufficient to guide home breathing practice.
Answers are grounded in this paper and cite their sources.
Individual resonance frequency breathing rates lack stability for tailoring; should not yet guide personalized interventions and requires larger validation studies.
An individual's resonance frequency (RF) is considered the optimal breathing rate for eliciting cardiovascular and autonomic benefits and is often used to guide home breathing practice. However, evidence on the stability of RF over time is scarce. Previous research reported poor 1 week test-retest reliability in a small sample. The present study aimed to replicate and extend these findings in a larger community sample while adhering to an RF determination pro. Fifty-one participants completed a 1-week test-retest assessment of RF. Group-level RF remained stable, but individual-level stability was low (ICC = 0.10), with approximately 25% of participants showing differences larger than 0.5 breaths per minute. Trend-level associations indicated that higher physical activity and more use of acceptance and self-support emotion regulation skills were linked to smaller RF test-retest variability. This study demonstrates that resonance frequency breathing is not equally stable across individuals, with a substantial subset showing meaningful shifts over just 1 week. By identifying lifestyle and emotion regulation factors linked to greater stability, our findings challenge the assumption that a single RF assessment is sufficient. This work advances the field by highlighting when individualized RF may (and may not) offer added value in practice. These findings suggest that RF is not uniformly stable across individuals, raising questions about the necessity and clinical relevance of repeated or individualized RF assessment. Future research should examine for whom RF remains stable and whether tailoring breathing rates provides measurable physiological or clinical benefits.
No takes yet. Share an insight, caveat, or question.
Depoorter et al. (2026) reported an observational. Resonance frequency breathing assessment was evaluated on 1-week test-retest stability of individual resonance frequency breathing rate (ICC 0.10). Resonance frequency breathing showed low individual-level 1-week test-retest stability (ICC = 0.10), with ~25% of participants shifting by >0.5 breaths/min.
Synapse has enriched 10 related papers. Consider them for comparative context: