Answers are grounded in this paper and cite their sources.
Background/Objectives: LC–MS/MS-based Multi-Attribute Method (MAM) workflows are increasingly used to characterize biotherapeutic proteins using peptide mapping and site-specific monitoring of critical quality attributes (CQAs). Sample preparation can impact foulant carryover, digestion efficiency, host cell protein (HCP) detection, and can induce artifactual chemical modifications. Herein, we compared a published National Institute for Bioprocessing Research and Training (NIBRT) MAM workflow with the S-Trap™ MAM Kit using NISTmAb RM 8671 with and without foulants. Methods: Both bottom-up workflows used tryptic digestion, performed in solution for NIBRT and on-trap for the S-Trap™ MAM Kit. Matched samples were prepared with or without added foulants from a panel of 42 bioprocess-relevant contaminants including salts, buffers, surfactants, stabilizers, and excipients. LC–MS/MS analysis compared peptide-mapping performance, foulant carryover, sequence coverage, HCP detection and background signals, as well as preparation-induced modifications, in particular deamidation. Protein recovery and complementary Tryp-N™ digestion were also evaluated. Results: Compared with the NIBRT workflow, the S-Trap™ MAM Kit had higher NISTmAb protein recovery (92.3% versus 48.4%); both workflows yielded full sequence coverage given matched peptide input. The S-Trap™ workflow produced greater total LC–MS signal from non-product proteins like HCPs. Under the conditions evaluated, signals corresponding to polysorbate-80, Brij-35, PEG-8000 and other contaminants were not detected following S-Trap™ preparation. Lower measured deamidation at the evaluated NISTmAb sites was observed using the kit and Tryp-N™ provided complementary peptide-mapping coverage. Conclusions: The S-Trap™ MAM Kit offers several advantages for NISTmAb sample preparation: higher recovery, greater LC-MS signal from non-product proteins like HCPs, lower overall deamidation, and no detectable signals from the examined surfactant and polymer foulants under the conditions evaluated. The standardized, plate-based workflow offers a promising approach for biotherapeutic MAM sample preparation. Broader applicability and suitability for use in quality-control require further product-specific qualification or validation. Data are available via ProteomeXchange with identifier PXD086642.
No takes yet. Share an insight, caveat, or question.
Scherzi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: