Answers are grounded in this paper and cite their sources.
A scaling law calibrated on data pooled from several facilities should be validated on a facility it has never seen, and when that test fails, the failure needs its own diagnosis: either the outcome carries a facility-specific effect that the predictors miss, or the predictor set itself cannot be separated from facility identity. We propose a two-stage protocol. The detection stage consists of algebraic-redundancy screening, leave-one-facility-out (LOFO) cross-validation, a facility-cluster bootstrap and a predictor/facility collinearity check; the diagnosis stage consists of a pre-fit identifiability index and a synthetic two-null discriminator. We apply it to 114 windage-power points from four sources (labelled by first author and year: Guo2024, Vrancik1968, Zheng2024, Liu2024) spanning a 900× Reynolds range. The corpus is heterogeneous: only 64 points are physical measurements, 45 are computational fluid dynamics (CFD) outputs for a facility that has not been built (including 8 rows with an inconsistent power basis and 7 with a frozen radial gap), 5 are reconstructed from a fitted constant, and 20 come from a preprint that has not been peer-reviewed. A four-predictor model selected by the Bayesian Information Criterion reaches an in-sample R2=0.870, but a pooled LOFO R2=−0.885, and no held-out facility is predicted better than its own mean. Repeating the structure selection inside each fold selects the same model in every fold. A pre-fit identifiability index shows that one direction of the predictor block, essentially logΠconfinement, is aliased with facility identity (the largest of the K−1=3 canonical correlations 0.996) and has almost no within-facility variation, also on a verified 94-row subset. With K=4 facilities, the two-null discriminator is fragile: under homoscedastic noise, 3 of 4 observed values fall outside both simulated supports; with per-point reported uncertainty, a facility-offset model reaches the observed values of Guo2024, Vrancik1968 and, in its extreme tail, Zheng2024, whereas a collinearity-only model with the same uncertainty does not reach Zheng2024 and reaches Guo2024 only at its 1st percentile, and Liu2024 is reached by neither; we therefore report it as a documented failure mode on small multi-facility corpora rather than as a standalone diagnostic. Twenty-one further attempts, sixteen of them learning methods, also fail the per-facility rule. Only the sign of the Reynolds effect transfers, and only among the physical facilities: within the CFD rows of the unbuilt facility, it is not detectable once 8 misattributed rows are separated.
No takes yet. Share an insight, caveat, or question.
Ruiz et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: