Key result
Emergency TEVAR normalizes visceral organ function and expands the true lumen through 8-month follow-up.
Why the study?
Inadvertent frozen elephant trunk deployment into the false lumen during type A aortic dissection repair is a rare, catastrophic complication causing true lumen collapse and visceral malperfusion, with limited reports on its endovascular management.
Case Report (n=1)
No
Endovascular reintervention using an additional stent graft to create a flow-redirection pathway is a feasible and effective salvage strategy for life-threatening true lumen collapse and visceral malperfusion caused by inadvertent FET deployment into the false lumen.
Answers are grounded in this paper and cite their sources.
May support endovascular salvage for FET maldeployment with malperfusion; hypothesis-generating and requires larger studies before wider adoption.
Introduction: Frozen elephant trunk (FET) was applied in the treatment of type A aortic dissection, enabling one-stage repair of the aortic arch and proximal descending aorta while promoting true lumen expansion. However, inadvertent FET deployment into the false lumen is a rare but catastrophic complication that may cause true lumen collapse and life-threatening visceral malperfusion, with limited reports on its endovascular management. Case presentation: Here, we present the case of a 44-year-old female who underwent Bentall procedure, total arch replacement, and FET implantation for acute type A aortic dissection at a local hospital. Postoperatively, she developed visceral malperfusion manifesting as abdominal distension, hepatic and renal dysfunction, and elevated lactate levels. Computed tomography angiography revealed that the FET stent had been inadvertently deployed into the false lumen, resulting in true lumen collapse. Emergency thoracic endovascular aortic repair was performed, establishing a "FET-false lumen-true lumen" pathway with an additional stent graft to redirect aortic flow into the true lumen. Computational fluid dynamics analysis showed that the postoperative hemodynamics have been significantly improved. The patient's organ function normalized, and she was discharged two weeks later, remaining asymptomatic at 8-month follow-up. Conclusion: Endovascular reintervention with additional stent grafting to establish a flow-redirection pathway is a feasible and effective strategy for true lumen collapse following inadvertent FET deployment into the false lumen. Prompt recognition, timely imaging confirmation, and immediate intervention are paramount to mitigating the risks associated with this serious complication.
No takes yet. Share an insight, caveat, or question.
Fan et al. (2026) conducted a case report in True lumen collapse and visceral malperfusion after inadvertent frozen elephant trunk deployment into the false lumen for acute type A aortic dissection (n=1). Emergency thoracic endovascular aortic repair (TEVAR) with an additional stent graft to establish a 'FET-false lumen-true lumen' flow-redirection pathway was evaluated on Resolution of visceral malperfusion, normalization of organ function, and true lumen expansion. Emergency thoracic endovascular aortic repair normalized visceral organ function and expanded the true lumen, leaving the patient asymptomatic at 8-month follow-up.
Synapse has enriched 10 related papers. Consider them for comparative context: