Key result
Larger preoperative aortic diameter is linked to ~29% higher fenestration-related leak risk per mm.
Why the study?
Objective anatomical criteria for selective fixation of the fenestration after fenestrated frozen elephant trunk are lacking, prompting an evaluation of the association between preoperative aortic morphology and fenestration-related leak.
Does preoperative aortic morphology and selective fenestration fixation influence the incidence of fenestration-related leak in patients with aortic dissection undergoing fenestrated frozen elephant trunk during total arch replacement?
Cohort (n=44)
Does preoperative aortic morphology and selective fenestration fixation influence the incidence of fenestration-related leak in patients with aortic dissection undergoing fenestrated frozen elephant trunk during total arch replacement?
In patients undergoing fenestrated frozen elephant trunk for aortic dissection, larger preoperative aortic diameter (especially >36 mm) and flat true lumen morphology are associated with a higher risk of postoperative fenestration-related leak, while intraoperative fixation is protective.
Answers are grounded in this paper and cite their sources.
Preoperative CT morphology may identify fenestration-leak risk after FET; leaves open prospective validation of selective fixation criteria.
OBJECTIVES: Objective anatomical criteria for selective fixation of the fenestration after fenestrated frozen elephant trunk (FET) are lacking. We examined the association between preoperative aortic morphology and fenestration-related leak. METHODS: We retrospectively analysed 44 consecutive patients with aortic dissection who underwent fenestrated FET during total arch replacement between 2021 and 2025. True aneurysms were excluded. Preoperative computed tomography (CT) was used to assess aortic short-axis diameter and true lumen (TL) morphology at three levels spanning the left subclavian artery origin. The outcome was fenestration-related leak, defined as persistent perigraft flow on the first postoperative contrast-enhanced CT scan before discharge. Comparisons used exact tests with Firth penalized logistic regression for adjusted associations. RESULTS: Leak occurred in 12 patients (27.3%): 3 of 26 (11.5%) with fixation and 9 of 18 (50.0%) without (P = 0.007). Aortic diameter was larger in patients with leak (34.5 vs 29.9 mm; P = 0.002; area under the curve 0.80, 95% CI 0.63-0.97), and leak incidence rose across diameter strata (12.5%, 57.1%, 80.0%; exact trend P = 0.001). Flat TL morphology was more frequent with leak (P = 0.025); TL position was not associated. Diameter remained associated after penalized adjustment (odds ratio 1.29 per mm; P = 0.001); fixation was independently protective (odds ratio, 0.07; P = 0.002). CONCLUSIONS: Fenestration-related leak was associated with larger preoperative aortic diameter and flat TL morphology, most evidently above 36 mm. Because fixation was chosen intraoperatively and few events occurred, these findings are exploratory and require prospective validation before they can be used to guide selective fixation.
No takes yet. Share an insight, caveat, or question.
Ikebata et al. (2026) conducted a cohort in Aortic dissection (n=44). Preoperative aortic short-axis diameter and true lumen morphology (with or without selective fenestration fixation) vs. No fenestration fixation / smaller aortic diameter was evaluated on Fenestration-related leak, defined as persistent perigraft flow on the first postoperative contrast-enhanced CT scan before discharge (OR 1.29 per mm for aortic diameter; OR 0.07 for fixation, p=0.001). Larger preoperative aortic diameter increased fenestration-related leak risk (OR 1.29 per mm, P=0.001), whereas fenestration fixation reduced leak rates (11.5% vs 50.0%; OR 0.07, P=0.002).