Background In robotic-assisted total knee arthroplasty (TKA), achieving soft-tissue balance requires repeated intraoperative plan adjustment and remains experience-dependent. Predictive models may support planning, but their clinical value depends on whether model-generated plans approximate predefined target gaps within the robotic workflow. This study assessed the software-based concordance between model-generated plans and predefined target gaps in robotic-assisted TKA. The predefined target gaps were planning set points established within the robotic software rather than measured intraoperative gaps. Methods This retrospective software-based concordance study included 209 complete-case knees undergoing robotic-assisted TKA. A machine-learning-based predictive model generated a bone-resection plan, which was imported into the robotic planning software to calculate software-derived medial and lateral gaps in extension and flexion. These software-derived gaps were compared with predefined target gaps, which were planning set points rather than measured values and were 18 mm in 819 of 836 gap-level observations (98.0%). The primary analysis focused on target gap deviation, defined as the software-derived gap minus the predefined target gap. As a benchmark, the deviation of the preadjustment gaps from the same targets was used as a preadjustment reference. Results A total of 836 gap-level observations were analyzed. The overall mean target gap deviation was −0.142 mm (SD, 1.411 mm), with a mean absolute error of 1.016 mm. Overall, 77.6% of software-derived gaps were within ±1 mm of target, and 93.4% were within ±2 mm. Bland–Altman analysis showed a small overall bias of −0.142 mm, with 95% limits of agreement from −2.91 to +2.62 mm. At the knee level, only 43.1% of knees had all software-derived gaps within ±1 mm of target. Gap-level deviations ranged from −7 mm to +5 mm, and 16.3% of knees (34/209) had at least one gap with an absolute deviation > 2 mm. Compared with the preadjustment reference (MAE 2.002 mm, 49.4% within ±1 mm), the model substantially reduced deviation (MAE 1.016 mm, 77.6% within ±1 mm, p < 0.001). Conclusions In this software-based concordance analysis, the predictive planning model generated surgical plans whose robotic software-derived gaps approximated predefined target gaps with a mean absolute deviation of approximately 1 mm. The model-generated plan reduced target-gap deviation relative to the initial preadjustment plan within this target-conditioned workflow. However, because the targets were near-uniform (98.0% at 18 mm) and all measurements were software-derived, compartment-specific bias, moderate whole-knee consistency (43.1%), and occasional outlier deviations indicate that the model should be used as a surgeon-supervised decision support tool rather than as an autonomous planner. Prospective validation against measured intraoperative and postoperative gaps is required before clinical effectiveness can be claimed.
No takes yet. Share an insight, caveat, or question.
Hu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: