Key result
ILR screening fails to reduce stroke or systemic arterial embolism compared with usual care.
Why the study?
It was unknown whether screening for atrial fibrillation with an implantable loop recorder and subsequent anticoagulation upon detection can prevent stroke in high-risk individuals.
Does continuous electrocardiographic monitoring using an implantable loop recorder with subsequent anticoagulation for episodes lasting 6 minutes or longer prevent stroke or systemic arterial embolism in older individuals with stroke risk factors?
RCT (n=6,004)
1:3 ratio via an online system in permuted blocks with block sizes of four or eight stratified according to centre
Yes
Does continuous electrocardiographic monitoring using an implantable loop recorder with subsequent anticoagulation for episodes lasting 6 minutes or longer prevent stroke or systemic arterial embolism in older individuals with stroke risk factors?
In older adults with stroke risk factors, implantable loop recorder screening tripled atrial fibrillation detection and anticoagulation initiation but did not significantly reduce the risk of stroke or systemic arterial embolism.
Answers are grounded in this paper and cite their sources.
ILR AF screening does not reduce stroke despite more anticoagulation; challenges broad use and leaves open targeted strategies.
BACKGROUND It is unknown whether screening for atrial fibrillation and subsequent treatment with anticoagulants if atrial fibrillation is detected can prevent stroke. Continuous electrocardiographic monitoring using an implantable loop recorder (ILR) can facilitate detection of asymptomatic atrial fibrillation episodes. We aimed to investigate whether atrial fibrillation screening and use of anticoagulants can prevent stroke in individuals at high risk. METHODS We did a randomised controlled trial in four centres in Denmark. We included individuals without atrial fibrillation, aged 70-90 years, with at least one additional stroke risk factor (ie, hypertension, diabetes, previous stroke, or heart failure). Participants were randomly assigned in a 1:3 ratio to ILR monitoring or usual care (control) via an online system in permuted blocks with block sizes of four or eight participants stratified according to centre. In the ILR group, anticoagulation was recommended if atrial fibrillation episodes lasted 6 min or longer. The primary outcome was time to first stroke or systemic arterial embolism. This study is registered with ClinicalTrials.gov, NCT02036450. FINDINGS From Jan 31, 2014, to May 17, 2016, 6205 individuals were screened for inclusion, of whom 6004 were included and randomly assigned: 1501 (25·0%) to ILR monitoring and 4503 (75·0%) to usual care. Mean age was 74·7 years (SD 4·1), 2837 (47·3%) were women, and 5444 (90·7%) had hypertension. No participants were lost to follow-up. During a median follow-up of 64·5 months (IQR 59·3-69·8), atrial fibrillation was diagnosed in 1027 participants: 477 (31·8%) of 1501 in the ILR group versus 550 (12·2%) of 4503 in the control group (hazard ratio [HR] 3·17 [95% CI 2·81-3·59]; p<0·0001). Oral anticoagulation was initiated in 1036 participants: 445 (29·7%) in the ILR group versus 591 (13·1%) in the control group (HR 2·72 [95% CI 2·41-3·08]; p<0·0001), and the primary outcome occurred in 318 participants (315 stroke, three systemic arterial embolism): 67 (4·5%) in the ILR group versus 251 (5·6%) in the control group (HR 0·80 [95% CI 0·61-1·05]; p=0·11). Major bleeding occurred in 221 participants: 65 (4·3%) in the ILR group versus 156 (3·5%) in the control group (HR 1·26 [95% CI 0·95-1·69]; p=0·11). INTERPRETATION In individuals with stroke risk factors, ILR screening resulted in a three-times increase in atrial fibrillation detection and anticoagulation initiation but no significant reduction in the risk of stroke or systemic arterial embolism. These findings might imply that not all atrial fibrillation is worth screening for, and not all screen-detected atrial fibrillation merits anticoagulation. FUNDING Innovation Fund Denmark, The Research Foundation for the Capital Region of Denmark, The Danish Heart Foundation, Aalborg University Talent Management Program, Arvid Nilssons Fond, Skibsreder Per Henriksen, R og Hustrus Fond, The AFFECT-EU Consortium (EU Horizon 2020), Læge Sophus Carl Emil Friis og hustru Olga Doris Friis' Legat, and Medtronic.
No takes yet. Share an insight, caveat, or question.
Svendsen et al. (2021) conducted an RCT in High risk for stroke without known atrial fibrillation (n=6,004). Implantable loop recorder (ILR) monitoring with anticoagulation recommended for atrial fibrillation episodes lasting >= 6 min vs. Usual care was evaluated on Time to first stroke or systemic arterial embolism (HR 0.80, 95% CI 0.61-1.05, p=0.11). Implantable loop recorder screening did not significantly reduce stroke or systemic arterial embolism compared with usual care (4.5% vs 5.6%; HR 0.80; 95% CI 0.61-1.05; p=0.11).
Synapse has enriched 10 related papers. Consider them for comparative context: