This is the authors' abstract. We don't add key points for this paper.
Electroencephalogram (EEG)-based classification of ictal, interictal, and normal segments is a core building block of automated seizure-monitoring systems. Existing deep models still struggle to jointly optimize sensitivity, specificity, cross-subject generalization, and computational cost. Motivated by the multi-rhythm structure of EEG, this study proposes an Adaptive Temporal-Scale Mamba with Rhythm-Aware Gating (ATSM-RAG) model. A Rhythm-Aware Gating (RAG) unit maps the relative band power of each EEG segment to a scalar gate that interpolates the discretization step (the effective temporal scale) of a Mamba state-space backbone, adapting the temporal receptive field to the input’s spectral state rather than relying on a fixed time constant. ATSM-RAG is evaluated on two public corpora under patient-independent protocols, and we foreground the two evaluations that are free of cross-corpus confounds. First, on the confound-free binary CHB-MIT benchmark (ictal versus interictal, patient-level leave-one-patient-out cross-validation, 22 folds), ATSM-RAG achieves an accuracy of 99.62% ± 0.35%, a sensitivity of 99.10% ± 0.95%, and a specificity of 99.75% ± 0.30%. Second, following the SzCORE recommendations, event-based scoring on all common-montage CHB-MIT recordings (633 files, 930.6 hours, 165 annotated seizures) yields an event-level sensitivity of 90.3% at 2.4 false alarms per 24 hours, with a median detection latency of 12.3 seconds. For completeness, the ternary benchmark (288 ictal and 1,440 interictal CHB-MIT segments plus 720 normal segments drawn from clinically normal recordings of the TUH Abnormal EEG Corpus) yields an accuracy of 99.51% ± 0.37%, a sensitivity (ictal recall) of 98.99% ± 1.29%, and a specificity (correct-classification rate of the merged non-ictal classes) of 99.58% ± 0.39%. On the TUH EEG Seizure Corpus (official patient-disjoint train/development/evaluation split), ATSM-RAG achieves a binary segment classification accuracy of 97.94%. Ablation experiments show that removing the RAG unit and fixing the temporal scale reduce accuracy by 2.94% and 2.05%, respectively. These results indicate that rhythm-conditioned temporal scaling is a promising and computationally efficient inductive bias for EEG segment classification; prospective and multi-center clinical validation is still required before any clinical deployment.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Lian et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: