Key result
Cerebral embolic protection during TAVI fails to reduce 30-day stroke risk compared to unprotected TAVI.
Why the study?
Cerebral embolic protection (CEP) devices were developed to reduce postoperative neurological outcomes after TAVI, but their effectiveness remains controversial.
Does the use of cerebral embolic protection devices during TAVI reduce the occurrence of all strokes and secondary clinical outcomes in patients undergoing TAVI?
Meta-Analysis (n=11,589)
Blinded randomized clinical trials
Included blinded randomized clinical trials (some with 2:1 allocation and roll-in process)
Does the use of cerebral embolic protection devices during TAVI reduce the occurrence of all strokes and secondary clinical outcomes in patients undergoing TAVI?
Answers are grounded in this paper and cite their sources.
In this meta-analysis and trial sequential analysis of 8 RCTs (11,589 patients), cerebral embolic protection during TAVI showed no statistically significant reduction in all-cause or disabling stroke, with trial sequential analysis confirming futility for all-cause mortality reduction and insufficient sample size for definitive conclusions on cerebrovascular outcomes.
Cerebral embolic protection (CEP) devices have been developed to reduce postoperative neurological outcomes after transcatheter aortic valve implantation (TAVI); however, their effectiveness remains controversial. To evaluate the impact of CEP use during TAVI on the occurrence in clinical outcomes. Databases were used to search for randomized clinical trials. The occurrence of all strokes, of disabling strokes specifically, transient ischemic attacks (TIAs), all-cause mortality, and vascular complications were analyzed. Conventional meta-analysis was conducted using fixed-effects modeling and trial sequential analysis (TSA: type I error of 5%, power of 90%). The systematic review protocol was registered on the International Prospective Register of Systematic Reviews (PROSPERO; CRD420251081075). In total, eight clinical trials were included, gathering 11,589 patients randomized between those who used the devices (5,943) and those who did not (5,646). The meta-analysis demonstrated no significant association between CEP use and reduced odds of all-cause stroke (OR = 0.92, 95% CI: 0.73–1.15, p = 0.46) and disabling stroke (OR = 0.80, 95% CI: 0.57–1.13, p = 0.20). The sequential analysis identified a lack of evidence for all strokes (required sample size [rSS] = 38,626; 10.53%), disabling strokes (rSS = 59,732; 17.05%). In terms of mortality, there was no significance in the use of devices (OR = 1.09, 95% CI: 0.71–1.69, p = 0.69), reaching evidence for support (rSS = 7,053; 42.25%); The data on the use of CEP is insufficient to support meta-analytic conclusions regarding cerebrovascular outcomes. Nevertheless, TSA demonstrated evidence supporting futility regarding mortality reduction.
No takes yet. Share an insight, caveat, or question.
Costa et al. (2026) conducted a meta-analysis in Aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) (n=11,589). Cerebral embolic protection (CEP) devices during TAVI (Sentinel, Claret Medical, TriGuard) vs. TAVI without cerebral embolic protection devices was evaluated on All strokes within 30 days (OR 0.92, 95% CI 0.73–1.15, p=0.46). Cerebral embolic protection devices during TAVI did not significantly reduce the odds of all-cause stroke compared to TAVI without protection (OR 0.92, 95% CI 0.73–1.15, p = 0.46).
Synapse has enriched 10 related papers. Consider them for comparative context: