Answers are grounded in this paper and cite their sources.
To address the challenge that it is difficult to accurately predict the evolution laws of the flow field and structural field of an aero-engine afterburner heat shield under high-temperature and high-pressure operating conditions, a numerical simulation study of thermal-fluid-solid coupling for the afterburner heat shield was performed using the ANSYS Workbench software. A periodic sector model of the heat shield was established. The effects of varying the mainstream temperature (750–1,250 K) and coolant mass flow rate (0.15–0.35 kg/s) on the heat shield performance, stress, and deformation were investigated. The simulations showed that raising the mainstream temperature from 750 to 1,250 K barely altered the static pressure in the mainstream passage but reduced the cooling effectiveness of the afterburner heat shield by 4.62 %. Increasing the coolant mass flow rate from 0.15 to 0.35 kg/s significantly raised the static pressure in the coolant passage and improved the cooling effectiveness by 41.18 %. A higher mainstream temperature concurrently increased both the stress and deformation of the heat shield, whereas a larger coolant flow rate decreased the deformation but elevated the structural stress. These findings provide a theoretical basis for afterburner heat shield thermal design.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: