Presence of His-bundle injury current during permanent His-bundle pacing was associated with significantly lower pacing thresholds at 1 year compared to its absence (1.3 vs 1.98 V, P<0.05).
Observational (n=60)
Sick sinus syndrome or atrioventricular block requiring permanent His-bundle pacing (n=60)
Presence of His-bundle injury current (HBIC) vs Absence of His-bundle injury current
Pacing threshold at 1 year (V @ 0.5 ms), p=< 0.05
Absolute Event Rate: 1.3% vs 1.98%
p-value: p=< 0.05
INTRODUCTION: His-bundle (HB) pacing (P) is a physiological alternative to right ventricular pacing (RVP), but is technically challenging and limited by higher pacing thresholds. Myocardial injury current (IC) recorded during right ventricular lead placement implies good tissue contact and is associated with low-pacing thresholds. IC at the HB has not been previously described. We hypothesized that HBIC during permanent HBP may be associated with lower pacing thresholds. METHODS: Permanent HBP was performed using Medtronic Select Secure(tm) (Medtronic Inc., Minneapolis, MN, USA) delivered via a fixed-curve (C315 His) sheath. HB electrogram (EGM) was recorded in a unipolar fashion from the lead tip. Presence or absence of HBIC was documented. HBP threshold, sensing, and impedances were recorded at implant, 2 weeks, 2 months, and 1 year. RESULTS: Sixty patients (age 72 ± 15 years; male 55%, sick sinus syndrome 40%, atrioventricular block 60%, fluoroscopy duration 9.2 ± 3.7 minutes) underwent successful permanent HBP. HBIC was recorded in 22 (37%) patients (group I). HBEGM without IC was recorded in the remaining 38 (63%) patients (group II). Pacing threshold at implant, 2 weeks, 2 months, and 1 year were significantly lower in group I (1.16 ± 0.4 V; 1.18 ± 0.5 V; 1.23 ± 0.6 V; 1.3 ± 0.6 V @ 0.5 ms) compared to group II (1.75 ± 0.7 V; 1.82 ± 0.8 V; 1.93 ± 0.8 V; 1.98 ± 0.9 V @ 0.5 ms, P < 0.05), respectively. CONCLUSIONS: IC can be recorded at the HB during permanent HBP in 37% of patients. HBIC is associated with significantly lower pacing thresholds compared to patients in whom HBIC was not recorded. HBIC may be a marker for superior short-term HBP thresholds.
Building similarity graph...
Analyzing shared references across papers
Loading...
Pugazhendhi Vijayaraman
Electrophysiology
Gopi Dandamudi
Prisma Health
Sarah Ann Worsnick
Heart Rhythm Society
Pacing and Clinical Electrophysiology
Virginia Commonwealth University
University Health System
Building similarity graph...
Analyzing shared references across papers
Loading...
Vijayaraman et al. (Wed,) conducted a observational in Sick sinus syndrome or atrioventricular block requiring permanent His-bundle pacing (n=60). Presence of His-bundle injury current (HBIC) vs. Absence of His-bundle injury current was evaluated on Pacing threshold at 1 year (V @ 0.5 ms) (p=< 0.05). Presence of His-bundle injury current during permanent His-bundle pacing was associated with significantly lower pacing thresholds at 1 year compared to its absence (1.3 vs 1.98 V, P<0.05).
synapsesocial.com/papers/6a0f22741cf410a932426584 — DOI: https://doi.org/10.1111/pace.12571