Systolic M-mode annulus excursion showed better inter-observer reproducibility (mean error 4%, P=0.001) than other traditional and newer measurements of left ventricular function.
Observational (n=10)
Healthy subjects (n=10)
Systolic M-mode annulus excursion vs Other traditional and newer measurements of LV function
Inter-observer mean error, p=0.001
p-value: p=0.001
AIMS: The study aimed to compare the inter-observer reproducibility of new and traditional measurements of the left ventricular (LV) global and regional function. METHODS AND RESULTS: Two experienced echocardiographers performed 20 complete echo/Doppler examinations and 50 analyses on ten healthy subjects. All recordings were analysed for systolic and diastolic conventional and deformation measurements by both echocardiographers. Inter-observer mean error (absolute difference divided by the mean) was 4% and lowest (P = 0.001) for systolic M-mode annulus excursion. Mean error for the regional deformation indices was significantly higher than for all the global measurements (all P < 0.001). Mean error for analyses of the same recording was 34% (P = 0.002) lower for global systolic indices and 44% (P < 0.001) lower for global diastolic indices than inter-observer mean error for analyses made in separate recordings. CONCLUSION: Systolic M-mode annulus excursion showed better inter-observer reproducibility than other traditional and newer measurements of LV systolic and diastolic function. Repeated analyses of the same recordings underestimate the more clinically relevant inter-observer reproducibility by approximately 40% for most measurements of LV function.
Building similarity graph...
Analyzing shared references across papers
Loading...
Anders Thorstensen
Norwegian University of Science and Technology
Håvard Dalen
Cardiac Imaging
Brage H. Amundsen
Norwegian University of Science and Technology
European Journal of Echocardiography
Norwegian University of Science and Technology
St Olav's University Hospital
Levanger Hospital
Building similarity graph...
Analyzing shared references across papers
Loading...
Thorstensen et al. (Thu,) conducted a observational in Healthy subjects (n=10). Systolic M-mode annulus excursion vs. Other traditional and newer measurements of LV function was evaluated on Inter-observer mean error (p=0.001). Systolic M-mode annulus excursion showed better inter-observer reproducibility (mean error 4%, P=0.001) than other traditional and newer measurements of left ventricular function.
synapsesocial.com/papers/6a0c649a106bfae8518868b7 — DOI: https://doi.org/10.1093/ejechocard/jep188