Fractional flow reserve derived from pressure measurements correlated closely to relative flow reserve from PET (r = 0.87) in patients with coronary artery stenosis.
Does fractional flow reserve derived from pressure measurements correlate with relative flow reserve derived from PET in patients with isolated LAD stenosis?
Patients with anginal chest pain caused by an isolated, discrete lesion of the proximal or mid left anterior descending coronary artery and normal left ventricular function
Fractional flow reserve (FFR) calculation from intracoronary pressure measurements during adenosine-induced maximal vasodilation
Relative myocardial flow reserve assessed by 15O-labeled water positron emission tomography (PET) and quantitative coronary angiography
Correlation between relative flow reserve obtained by PET and fractional flow reserve obtained by pressure recordingssurrogate
Fractional flow reserve derived from intracoronary pressure measurements correlates closely with PET-derived relative flow reserve, validating its use as a physiological index of coronary stenosis severity.
Absolute Event Rate: 0% vs 0%
BACKGROUND Experimental studies have shown that fractional flow reserve (defined as the ratio of maximal achievable flow in a stenotic area to normal maximal achievable flow) can be calculated from coronary pressure measurements only. The objectives of this study were to validate fractional flow reserve calculation in humans and to compare this information with that derived from quantitative coronary angiography. METHODS AND RESULTS Twenty-two patients with an isolated, discrete proximal or mid left anterior descending coronary artery stenosis and normal left ventricular function were studied. Relative myocardial flow reserve, defined as the ratio of absolute myocardial perfusion during maximal vasodilation in the stenotic area to the absolute myocardial perfusion during maximal vasodilation (adenosine 140 micrograms.kg-1 x min-1 intravenously during 4 minutes) in the contralateral normally perfused area, was assessed by 15O-labeled water and positron emission tomography (PET). Myocardial and coronary fractional flow reserve were calculated from mean aortic, distal coronary, and right atrial pressures recorded during maximal vasodilation. Distal coronary pressures were measured by an ultrathin, pressure-monitoring guide wire with minimal influence on the trans-stenotic pressure gradient. Minimal obstruction area, percent area stenosis, and calculated stenosis flow reserve were assessed by quantitative coronary angiography. There was no difference in heart rate, mean aortic pressure, or rate-pressure product during maximal vasodilation during PET and during catheterization. Percent area stenosis ranged from 40% to 94% (mean, 77 +/- 13%), myocardial fractional flow reserve from 0.36 to 0.98 (mean, 0.61 +/- 0.17), and relative flow reserve from 0.27 to 1.23 (mean, 0.60 +/- 0.26). A close correlation was found between relative flow reserve obtained by PET and both myocardial fractional flow reserve (r = .87) and coronary fractional flow reserve obtained by pressure recordings (r = .86). The correlations between relative flow reserve obtained by PET and stenosis measurements derived from quantitative coronary angiography were markedly weaker (minimal obstruction area, r = .66; percent area stenosis, r = -.70; and stenosis flow reserve, r = .68). CONCLUSIONS Fractional flow reserve derived from pressure measurements correlates more closely to relative flow reserve derived from PET than angiographic parameters. This validates in humans the use of fractional flow reserve as an index of the physiological consequences of a given coronary artery stenosis.
Building similarity graph...
Analyzing shared references across papers
Loading...
Bernard De Bruyne
Università Cattolica del Sacro Cuore
T. Baudhuin
Hammersmith Hospital
Jacques Melin
Cliniques Universitaires Saint-Luc
Circulation
Building similarity graph...
Analyzing shared references across papers
Loading...
Bruyne et al. (Tue,) reported a other. Fractional flow reserve derived from pressure measurements correlated closely to relative flow reserve from PET (r = 0.87) in patients with coronary artery stenosis.
synapsesocial.com/papers/6970ddc7da50910f9664e715 — DOI: https://doi.org/10.1161/01.cir.89.3.1013
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: