Strain-encoded MR imaging identified a greater extent of dysfunctional myocardium than delayed contrast-enhanced MR (P<.05) and strongly correlated with 3D tagged MR imaging (r=0.75, P<.001).
Observational (n=14)
Myocardial infarction (n=14)
Strain-encoded MR imaging vs Delayed contrast-enhanced MR imaging and three-dimensional tagged MR imaging
Correlation of strain values between strain-encoded MR imaging and three-dimensional tagged MR imaging — r = 0.75, p=< .001
Effect estimate: r = 0.75
p-value: p=< .001
Strain-encoded magnetic resonance (MR) imaging was prospectively evaluated for direct imaging of systolic myocardial strain and compared with cross-registered delayed contrast material-enhanced MR imaging in five healthy volunteers and nine patients with infarction. Local contractile performance was decreased in infarcted myocardium versus that in remote and adjacent myocardium (P < .01) and in adjacent versus remote myocardium (P < .05). The extent of dysfunctional myocardium, as assessed with strain-encoded MR imaging, was greater than that of hyperenhancement, as assessed with delayed contrast-enhanced MR imaging (P < .05). Strain values obtained with strain-encoded MR imaging were strongly correlated with those obtained with three-dimensional tagged MR imaging (r = 0.75, P < .001). Strain-encoded MR imaging provides spatially resolved (1.5 x 2.5-mm) imaging and measurement of myocardial strain in humans without the need for postprocessing, which may improve routine comprehensive evaluation of myocardial viability.
Building similarity graph...
Analyzing shared references across papers
Loading...
Jérôme Garot
Cardiac Imaging
João A.C. Lima
Cardiac Imaging
Bernhard Gerber
Cardiac Imaging
Radiology
Johns Hopkins University
Building similarity graph...
Analyzing shared references across papers
Loading...
Garot et al. (Mon,) conducted a observational in Myocardial infarction (n=14). Strain-encoded MR imaging vs. Delayed contrast-enhanced MR imaging and three-dimensional tagged MR imaging was evaluated on Correlation of strain values between strain-encoded MR imaging and three-dimensional tagged MR imaging (r = 0.75, p=< .001). Strain-encoded MR imaging identified a greater extent of dysfunctional myocardium than delayed contrast-enhanced MR (P<.05) and strongly correlated with 3D tagged MR imaging (r=0.75, P<.001).
synapsesocial.com/papers/6a0f6ed09e54838161fcb6c0 — DOI: https://doi.org/10.1148/radiol.2332031676