Zn – Mn O 2 alkaline batteries were investigated in situ at different stages of electric discharge by synchrotron tomography with monochromatic x rays and by neutron tomography. The spatial distribution and the changes in the morphology of different components of a battery caused by the reduction of MnO2, the dissolution of Zn, and the nucleation and growth of ZnO are investigated with high spatial resolution around several micrometers with x rays. Neutron tomography is used to monitor the changes in the spatial distribution of hydrogen in the MnO2 matrix and provides complementary information about the process.
Manke et al. (Mon,) studied this question.