An implantable defibrillator resulted in 0% mortality compared to 26% with pharmacological therapy and 31% with no therapy in patients with RBBB and ST elevation in V1-V3 (P=0.0005).
Cohort (n=63)
Yes
Right bundle-branch block and ST-segment elevation in leads V1 through V3 without structural heart disease (n=63)
Implantable defibrillator vs Pharmacological therapy or no treatment
Total mortality, p=0.0005
Absolute Event Rate: 0% vs 31%
p-value: p=0.0005
BACKGROUND: Five years ago, we described a specific ECG pattern of right bundle-branch block and ST-segment elevation in leads V1 through V3 associated with sudden death in patients without demonstrable structural heart disease. Information on long-term outcome has become available due to pooled data on a large cohort of patients with this syndrome who are followed at 33 centers worldwide. METHODS AND RESULTS: Data on 63 patients (57 men; mean age, 38+/-17 years) with the described ECG pattern were analyzed in terms of arrhythmic events and sudden death. Events were analyzed for patients with at least one episode of aborted sudden death or syncope of unknown origin before recognition of the syndrome (symptomatic patients, n=41) and for patients in whom the ECG pattern was recognized by chance or because of screening related to sudden death of a relative (asymptomatic patients, n=22). During a mean follow-up of 34+/-32 months, an arrhythmic event occurred in 14 symptomatic patients (34%) and 6 asymptomatic patients (27%). An automatic defibrillator was implanted in 35 patients, 15 received pharmacological therapy with beta-blockers and/or amiodarone, and 13 did not receive treatment The incidence of arrhythmic events was similar in all therapy groups (log-rank 0.86); however, total mortality was 0% in the implantable defibrillator group, 26% in the pharmacological group, and 31% in the no therapy group (log-rank 0.0005). All mortality was due to sudden death. CONCLUSIONS: Patients without demonstrable structural heart disease and an ECG pattern of right bundle-branch block and ST-segment elevation in leads V1 through V3 are at risk for sudden death. Amiodarone and/or beta-blockers do not protect them against sudden death, and an implantable defibrillator seems to be the present treatment of choice.
Building similarity graph...
Analyzing shared references across papers
Loading...
Josép Brugada
University of Southern California
Ramón Brugada
Università Cattolica del Sacro Cuore
Pedro Brugada
Vrije Universiteit Brussel
Circulation
Baylor College of Medicine
Building similarity graph...
Analyzing shared references across papers
Loading...
Brugada et al. (Tue,) conducted a cohort in Right bundle-branch block and ST-segment elevation in leads V1 through V3 without structural heart disease (n=63). Implantable defibrillator vs. Pharmacological therapy or no treatment was evaluated on Total mortality (p=0.0005). An implantable defibrillator resulted in 0% mortality compared to 26% with pharmacological therapy and 31% with no therapy in patients with RBBB and ST elevation in V1-V3 (P=0.0005).
synapsesocial.com/papers/6a0cfacdb31ab1d6e01e7474 — DOI: https://doi.org/10.1161/01.cir.97.5.457