T2-weighted BOLD imaging quantitatively estimated regional OEF (0.43±0.12 in abnormal vs 0.21±0.11 in normal myocardium) and approximated MPR (R=0.6-0.9 vs microspheres) in a canine model.
Can T2-weighted BOLD imaging estimate regional myocardial oxygen extraction fraction and approximate perfusion reserve in a canine model with coronary artery stenosis?
TSE-based BOLD imaging is feasible for quantitatively estimating regional myocardial oxygen extraction fraction and approximating perfusion reserve in the presence of coronary stenosis.
Absolute Event Rate: 0.43% vs 0.21%
PURPOSE: To determine the feasibility of T2-weighted BOLD imaging for estimating regional myocardial oxygen extraction fraction (OEF) and approximating perfusion reserve (MPR) simultaneously in a canine model with moderate coronary artery stenosis. MATERIALS AND METHODS: Eight mongrel dogs with moderate coronary artery stenosis underwent BOLD imaging at rest and during dipyridamole-induced hyperemia, using a turbo spin echo (TSE) sequence. Based on a two-compartment model, myocardial OEF(hyperemia) was calculated with the corresponding T2. MPR could be approximated based on Fick's law. RESULTS: During responsive hyperemia, a regional hypointensity was observed in the abnormally perfused myocardium, reflecting a relatively smaller myocardial T2 increase (3.06% +/- 2.74%, in contrast to 10.19% +/- 4.12% in the normal region). The average OEFs in the normally and abnormally perfused myocardial territories were 0.21 +/- 0.11 and 0.43 +/- 0.12, respectively. For the MPR approximated from the BOLD imaging, a strong correlation (R = 0.9) in the normal myocardium and a good correlation (R = 0.6) distal to the stenosis were obtained compared to microsphere results. CONCLUSION: In a canine model with moderate coronary artery stenosis, TSE-based BOLD imaging can quantitatively estimate the regional OEF(hyperemia) and approximate the MPR, and can distinguish segments perfused by defected coronary artery.
Zhang et al. (Sun,) conducted a other in moderate coronary artery stenosis (n=8). T2-weighted BOLD imaging vs. Normal myocardium / microspheres was evaluated on regional myocardial oxygen extraction fraction (OEF) and perfusion reserve (MPR). T2-weighted BOLD imaging quantitatively estimated regional OEF (0.43±0.12 in abnormal vs 0.21±0.11 in normal myocardium) and approximated MPR (R=0.6-0.9 vs microspheres) in a canine model.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: