Key result
T2-weighted BOLD imaging quantitatively estimated regional OEF (0.43±0.12 in abnormal vs 0.21±0.11 in normal myocardium) and approximated MPR (R=0.6-0.9 vs microspheres) in a canine model.
Why the study?
Can T2-weighted BOLD imaging estimate regional myocardial oxygen extraction fraction and approximate perfusion reserve in a canine model with coronary artery stenosis?
Can T2-weighted BOLD imaging estimate regional myocardial oxygen extraction fraction and approximate perfusion reserve in a canine model with coronary artery stenosis?
TSE-based BOLD imaging is feasible for quantitatively estimating regional myocardial oxygen extraction fraction and approximating perfusion reserve in the presence of coronary stenosis.
PURPOSE: To determine the feasibility of T2-weighted BOLD imaging for estimating regional myocardial oxygen extraction fraction (OEF) and approximating perfusion reserve (MPR) simultaneously in a canine model with moderate coronary artery stenosis. MATERIALS AND METHODS: Eight mongrel dogs with moderate coronary artery stenosis underwent BOLD imaging at rest and during dipyridamole-induced hyperemia, using a turbo spin echo (TSE) sequence. Based on a two-compartment model, myocardial OEF(hyperemia) was calculated with the corresponding T2. MPR could be approximated based on Fick's law. RESULTS: During responsive hyperemia, a regional hypointensity was observed in the abnormally perfused myocardium, reflecting a relatively smaller myocardial T2 increase (3.06% +/- 2.74%, in contrast to 10.19% +/- 4.12% in the normal region). The average OEFs in the normally and abnormally perfused myocardial territories were 0.21 +/- 0.11 and 0.43 +/- 0.12, respectively. For the MPR approximated from the BOLD imaging, a strong correlation (R = 0.9) in the normal myocardium and a good correlation (R = 0.6) distal to the stenosis were obtained compared to microsphere results. CONCLUSION: In a canine model with moderate coronary artery stenosis, TSE-based BOLD imaging can quantitatively estimate the regional OEF(hyperemia) and approximate the MPR, and can distinguish segments perfused by defected coronary artery.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2007) studied moderate coronary artery stenosis (n=8). T2-weighted BOLD imaging vs. Normal myocardium / microspheres was evaluated on regional myocardial oxygen extraction fraction (OEF) and perfusion reserve (MPR). T2-weighted BOLD imaging quantitatively estimated regional OEF (0.43±0.12 in abnormal vs 0.21±0.11 in normal myocardium) and approximated MPR (R=0.6-0.9 vs microspheres) in a canine model.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: