Transcatheter pacemaker implantation was safe and feasible in 6 pacemaker-dependent patients with severe device infection, with 100% remaining free of re-infection at 12 weeks.
Observational (n=6)
No
Severe device infection (n=6)
Transcatheter pacing system (TPS) implantation
Successful lead extraction and TPS implantation, and freedom from infection
BACKGROUND: Conventional pacemaker therapy is limited by short- and long-term complications, most notably device infection. Transcatheter pacing systems (TPS) may be beneficial in this kind of patients as they eliminate the need for a device pocket and leads and thus may reduce the risk of re-infection. METHODS: We assessed a novel procedure in 6 patients with severe device infection who were pacemaker dependent. After lead extraction a single chamber TPS was implanted into the right ventricle. RESULTS: Of the 6 patients who underwent lead extraction due to severe device infection at our institution, 3 were diagnosed with a pocket infection only, whereas the other 3 showed symptoms of both pocket and lead infection. Successful lead extraction and TPS implantation was accomplished in all patients. Four patients were bridged with a temporary pacemaker between 2 hours and 2 days after lead extraction, whereas 2 patients had the TPS implanted during the same procedure just before traditional pacemaker system removal. All patients stayed free of infection during the follow-up period of 12 weeks. An additional positron emission tomography scan was performed in each patient and indicated no signs of an infection around the TPS. CONCLUSION: Transcather pacemaker implantation was safe and feasible in 6 patients and did not result in re-infection even if implanted before removal of the infected pacemaker system within the same procedure. Therefore, implantation of a TPS may be an option for patients with severe device infection, especially in those with blocked venous access or who are pacemaker dependent.
Building similarity graph...
Analyzing shared references across papers
Loading...
Alexander Kypta
Johannes Kepler University of Linz
Hermann Blessberger
Electrophysiology
Juergen Kammler
Johannes Kepler University of Linz
Journal of Cardiovascular Electrophysiology
University of Salzburg
Johannes Kepler University of Linz
Paracelsus Medical University
Building similarity graph...
Analyzing shared references across papers
Loading...
Kypta et al. (Tue,) conducted a observational in Severe device infection (n=6). Transcatheter pacing system (TPS) implantation was evaluated on Successful lead extraction and TPS implantation, and freedom from infection. Transcatheter pacemaker implantation was safe and feasible in 6 pacemaker-dependent patients with severe device infection, with 100% remaining free of re-infection at 12 weeks.
synapsesocial.com/papers/6a0ee26e1c5e2d2319fa0843 — DOI: https://doi.org/10.1111/jce.13030