Cooking-related emissions represent a major contributor to indoor air pollution in residential kitchens, producing complex mixtures of volatile organic compounds (VOCs), odor-causing gases, oil vapors, particulate matter (PM2.5), and combustion-related pollutants (CO and NOx). In this study, a controlled ozone-assisted oxidation approach was integrated into a recirculating (ductless) domestic kitchen hood equipped with a confined reaction chamber and experimentally evaluated under closed-loop operating conditions where treated air was returned to the indoor environment after post-treatment. A multivariate Response Surface Methodology (RSM) framework based on the Box–Behnken design was employed to quantify and optimize the coupled effects of temperature (20–30 °C), relative humidity (40–60%), ozone dosage (1–3 ppm within the confined reaction zone), and airflow rate (150–250 m3/h) on multi-pollutant removal performance. The results demonstrate that ozone assistance substantially improves the abatement of oxidation-sensitive pollutants, particularly VOCs and odor, while airflow rate strongly governs transport-dominated pollutants such as PM2.5 and oil vapors. In contrast, CO and NOx exhibited limited improvement, indicating that ozone-assisted oxidation alone is insufficient for comprehensive control of combustion-related gases under short-residence-time recirculating hood conditions. The main contribution of this work is the implementation of a demand-driven ozone management strategy, supported by dual ozone sensing for reaction-zone control and outlet safety verification, where ozone generation is activated only in the presence of reactive gaseous pollutants and automatically reduced or terminated once pollutant concentrations fall below predefined thresholds, minimizing unnecessary oxidant release. Residual ozone downstream of the reaction stage was continuously monitored to prevent excess ozone return to the occupied zone. Overall, the proposed closed-loop, feedback-controlled ozone-assisted recirculating range hood concept demonstrated device-level reductions in measured VOC/odor signals under controlled conditions, while also highlighting the need for complementary post-treatment components for particle- and combustion-related pollutants. However, the potential formation of secondary oxidation byproducts was not characterized in this study, and therefore the results should be interpreted with respect to device-level pollutant removal rather than comprehensive indoor air quality improvement.
Özçetin et al. (Tue,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: