Indoor sports facilities present unique challenges for air quality management due to high crowd densities and limited ventilation. This study investigated air quality in a municipal athletic facility in Komotini, Greece, focusing on concentrations of airborne particulate matter (PM1.0, PM2.5, PM10), humidity, and temperature across spectator zones, under varying mask scenarios. Sensing devices were installed in the stands to collect high-frequency environmental data. The system, based on optical particle counters and cloud-enabled analytics, enabled real-time data capture and retrospective analysis. The main experiment investigated the impact of spectators wearing medical masks during two basketball games. The results show consistently elevated PM levels during games, often exceeding recommended international thresholds in the spectator area. Notably, the use of masks by spectators led to measurable reductions in PM1.0 and PM2.5 concentrations, because they seem to have limited the release of human-generated aerosols as well as the amount of movement among spectators, supporting their effectiveness in limiting fine particulate exposure in inadequately ventilated environments. Humidity emerged as a reliable indicator of occupancy and potential high-risk periods, making it a valuable parameter for real-time monitoring. The findings underscore the urgent need for improved ventilation strategies in small to medium-sized indoor sports facilities and support the deployment of low-cost sensor networks for actionable environmental health management.
Katsiri et al. (Thu,) studied this question.