Gas Bremsstrahlung: A Comparison of Measurements and Simulations

EAEsposito A.FAFerrari A.LLLiberatori L.

Key Points

  • This research aims to compare measured bremsstrahlung intensity from an electron beam with simulation results.
  • Measured absolute bremsstrahlung intensity as a function of angle and distance.
  • Used thermoluminescent dosimeters to measure absorbed doses at various distances.
  • Simulated the experiment using the FLUKA code for bremsstrahlung treatment.
  • Computed results align satisfactorily with measured intensities despite uncertainties in pressure.
  • Provided evidence for angular distribution of bremsstrahlung intensity at energies above 1 GeV.

Abstract

The absolute bremsstrahlung intensity generated by the interaction of the electron beam of the Adone storage ring of LNF has been measured as a function of angle and distance from the emitting straight section. Absorbed doses have been measured at variuos distances from the straight section by means of thermoluminescent dosimeters for a 1.5 GeV electron beam. The experiment has been simulated using the most recent version of the FLUKA code which includes a very accurate treatment of bremstrahlung. In spite of the considerable uncertainties on the experimental value of the pressure, it has been found that the computed results are in satisfactory agreement with the results of the measurements. The experiment provided also evidence for the angular distribution of the bremstrahlung intensity at energies in excess of 1 GeV.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

A. et al. (1993) studied this question.

synapsesocial.com/papers/69a91db5d6127c7a504c0d4bhttps://doi.org/10.15161/oar.it/np3sx-czb32
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1A Dose Comparison Between Gas Bremsstrahlung and Single Beam???Beam Bremsstrahlung at High Luminosity e+ e??? Storage Rings1994
  2. 2Gas Bremsstrahlung Evaluation for the DAFNE Project1993
  3. 3Estimation of Fluence Rate and Absorbed Dose Rate Due to Gas Bremsstrahlung from Electron Storage Rings1993
  4. 4Photon and neutron dose evaluation at the Beam Test Facility of the INFN - National Laboratory of Frascati2024
  5. 5Angular Distribution of Bremsstrahlung Spectral Temperature Measured in a Full Dimension of ECR Ion Source Using NaI(TI) Detector2024