Development and characteristics of a fast gas valve for plasma-jet-driven magneto-inertial Fusion (PJMIF)

View Full Paper
YLYanbin LiuYJYuantong JingYTY. C. Francis Thio

Key Points

  • The research aims to develop a fast gas valve to enhance gas injection for plasma guns in magneto-inertial fusion applications.
  • Design of a fast gas valve activated by eddy currents.
  • Use of a 7075 aluminum flyer plate for gas control.
  • Installation of displacement sensors to measure flyer plate distances.
  • Measurement of pressure changes with a capacitance diaphragm gauge.
  • Fast gas valve achieves open-close time of less than 230 μs, with a minimum of 102 μs.
  • Saucer spring design demonstrates superior performance over conventional springs.
  • Gas mass dispensed by the valve exhibits variation of less than 1%.
  • Maximum displacement variation at measuring points is under 7%.

Abstract

To provide rapid gas injection for the plasma gun developed at the CUE of ShanghaiTech University, a new fast gas valve activated by eddy currents has been designed and tested on an experimental facility. A 7075 aluminum flyer plate is used to control the gas injection process. A saucer spring is designed to provide pre-compression force and back force on the flyer plate. Four displacement sensors are installed vertically to the flyer plate to measure distances at four equally distributed points. A capacitance diaphragm gauge is used to measure pressure changes in the vacuum chamber. The main characteristics of the fast gas valve are as follows: (1) the open-close time (the opening to complete closure time) is less than 230 μs, with a minimum value of 102 μs; (2) a saucer spring is designed to provide pre-compression force on the flyer plate, which demonstrates better performance than conventional spiral springs; (3) the gas mass dispensed by the fast gas valve is highly stable, with an average variation of less than 1%; (4) the maximum variation in displacements at the four measuring points on the flyer plate is less than 7%. The fast gas valve has been tested with argon gas on the plasma gun and has shown good performance.