Answers are grounded in this paper and cite their sources.
Experimental facility tests a fast gas valve for gas injection in plasma-jet-driven fusion, indicating improved performance.
To provide rapid gas injection for the plasma gun developed at the CUE of ShanghaiTech University, a new fast gas valve activated by eddy currents has been designed and tested on an experimental facility. A 7075 aluminum flyer plate is used to control the gas injection process. A saucer spring is designed to provide pre-compression force and back force on the flyer plate. Four displacement sensors are installed vertically to the flyer plate to measure distances at four equally distributed points. A capacitance diaphragm gauge is used to measure pressure changes in the vacuum chamber. The main characteristics of the fast gas valve are as follows: (1) the open-close time (the opening to complete closure time) is less than 230 μs, with a minimum value of 102 μs; (2) a saucer spring is designed to provide pre-compression force on the flyer plate, which demonstrates better performance than conventional spiral springs; (3) the gas mass dispensed by the fast gas valve is highly stable, with an average variation of less than 1%; (4) the maximum variation in displacements at the four measuring points on the flyer plate is less than 7%. The fast gas valve has been tested with argon gas on the plasma gun and has shown good performance.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: