March 9, 2016Neurophotonics577 citationsOpen Access

False positives and false negatives in functional near-infrared spectroscopy: issues, challenges, and the way forward

ITIlias TachtsidisFSFelix Scholkmann

Key Points

  • This research aims to address the issues of false positives and negatives in functional near-infrared spectroscopy (fNIRS).
  • Review of physiological origins leading to false positives and negatives in fNIRS measurements.
  • Discussion of strategies for mitigating the misinterpretation of hemodynamic responses.
  • Identified significant potential for misinterpreting fNIRS data due to incorrect associations of hemodynamic responses.
  • Proposed several methods to enhance the accuracy of fNIRS readings and reduce misclassification.

Abstract

We highlight a significant problem that needs to be considered and addressed when performing functional near-infrared spectroscopy (fNIRS) studies, namely the possibility of inadvertently measuring fNIRS hemodynamic responses that are not due to neurovascular coupling. These can be misinterpreted as brain activity, i.e., "false positives" (errors caused by wrongly assigning a detected hemodynamic response to functional brain activity), or mask brain activity, i.e., "false negatives" (errors caused by wrongly assigning a not observed hemodynamic response in the presence of functional brain activity). Here, we summarize the possible physiological origins of these issues and suggest ways to avoid and remove them.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Tachtsidis et al. (2016) studied this question.

synapsesocial.com/papers/69d8330552654bb436d186aehttps://doi.org/10.1117/1.nph.3.3.031405
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Near‐infrared study of fluctuations in cerebral hemodynamics during rest and motor stimulation: Temporal analysis and spatial mapping2000 · 170 citations
  2. 2Cerebral hemodynamic and oxygenation changes induced by inner and heard speech: a study combining functional near-infrared spectroscopy and capnography2014 · 31 citations
  3. 3Why is the neural control of cerebral autoregulation so controversial?2014 · 92 citations
  4. 4Greater contribution of cerebral than extracerebral hemodynamics to near-infrared spectroscopy signals for functional activation and resting-state connectivity in infants2014 · 19 citations
  5. 5Separation of superficial and cerebral hemodynamics using a single distance time-domain NIRS measurement2014 · 26 citations