PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
November 1, 1979Circulation681 citations

Noninvasive assessment of atrioventricular pressure half-time by Doppler ultrasound.

View Full Paper
LHLiv HatleBAB. A. J. AngelsenATArve Tromsdal

Structured PICO

Can Doppler ultrasound noninvasively assess atrioventricular pressure half-time to accurately evaluate mitral valve disease severity?

P
Population
101 subjects, comprising 40 normal subjects, 17 patients with isolated mitral regurgitation, 32 patients with mitral stenosis, and 12 patients with combined mitral stenosis and regurgitation.
I
Intervention
Noninvasive measurement of atrioventricular pressure half-time and mean pressure drop across the mitral valve using Doppler ultrasound.
C
Comparator
Invasive catheterization data for calculation of mitral valve area (performed in a subset of 32 patients).
O
Outcome
Atrioventricular pressure half-time values across different patient groups and their relationship to invasively calculated mitral valve area.surrogate

Doppler ultrasound provides a reliable noninvasive method to measure atrioventricular pressure half-time, which correlates inversely with mitral valve area in patients with mitral stenosis.

Abstract

The mean pressure drop across the mitral valve and atrioventricular pressure half-time were measured noninvasively by Doppler ultrasound in 40 normal subjects, in 17 patients with mitral regurgitation, 32 patients with mitral stenosis and 12 with combined stenosis and regurgitation. In normal subjects pressure half-times were 20--60 msec, in patients with isolated mitral regurgitation 35--80 msec and in patients with mitral stenosis 90--383 msec. There was no significant change in pressure half-time with exercise or on repeat examinations, indicating relative independence of mitral flow. In 25 patients with mitral stenosis and seven with combined stenosis and regurgitation, pressure half-time was related to mitral valve area calculated from catheterization data. Increasing pressure half-times occurred with decreasing mitral valve area, and this relationship was not influenced by additional mitral regurgitation. Noninvasive measurement of pressure half-time together with mean pressure drop was useful for evaluating patients with mitral valve disease.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Hatle et al. (1979) studied this question.

synapsesocial.com/papers/69f2cb58be8e9f1f31c578fbhttps://doi.org/10.1161/01.cir.60.5.1096
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Modified orifice equation for the calculation of mitral valve area1972 · 185 citations
  2. 2Measurement of Left Ventricular Volumes in Man by Single-plane Cineangiocardiography1969 · 260 citations
  3. 3Evaluation of the Severity of Mitral Stenosis and Regurgitation1966 · 39 citations
  4. 4Diagnosis of valvular heart disease using transcutaneous Doppler ultrasound1977 · 60 citations
  5. 5Atrioventricular Pressure Half-Time1968 · 111 citations