PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 24, 2017Circulation365 citations

Transcatheter Treatment of Severe Tricuspid Regurgitation With the Edge-to-Edge MitraClip Technique

View Full Paper
GNGeorg NickenigMKMarek KowalskiJHJörg Hausleiter

Structured PICO

Is transcatheter repair with the MitraClip system safe and feasible in patients with heart failure symptoms and severe tricuspid regurgitation?

P
Population
Patients with heart failure symptoms and chronic severe tricuspid regurgitation (TR) on optimal medical treatment
I
Intervention
Transcatheter repair with the MitraClip system (implantation of 1 or more devices)
O
Outcome
Safety (periprocedural adverse events such as death, myocardial infarction, stroke, or cardiac tamponade) and feasibility (successful implantation of 1 or more MitraClip devices and reduction of TR by at least 1 grade) evaluated before discharge and after 30 dayssafety

Transcatheter edge-to-edge repair using the MitraClip system appears safe and feasible for treating severe tricuspid regurgitation, offering a potential interventional option for symptomatic patients.

Limitations

  • Preselected patient cohort
  • Observational design

Abstract

BACKGROUND: Current surgical and medical treatment options for severe tricuspid regurgitation (TR) are limited, and additional interventional approaches are required. In the present observational study, the safety and feasibility of transcatheter repair of chronic severe TR with the MitraClip system were evaluated. In addition, the effects on clinical symptoms were assessed. METHODS: Patients with heart failure symptoms and severe TR on optimal medical treatment were treated with the MitraClip system. Safety, defined as periprocedural adverse events such as death, myocardial infarction, stroke, or cardiac tamponade, and feasibility, defined as successful implantation of 1 or more MitraClip devices and reduction of TR by at least 1 grade, were evaluated before discharge and after 30 days. In addition, functional outcome, defined as changes in New York Heart Assocation class and 6-minute walking distance, were assessed. RESULTS: =0.007). CONCLUSIONS: Transcatheter treatment of TR with the MitraClip system seems to be safe and feasible in this cohort of preselected patients. Initial efficacy analysis showed encouraging reduction of TR, which may potentially result in improved clinical outcomes.