Key result
MitraClip for severe tricuspid regurgitation is safe, feasible, and significantly reduces TR at 30 days.
Why the study?
Current surgical and medical treatment options for severe tricuspid regurgitation are limited, requiring evaluation of the safety, feasibility, and symptomatic effects of transcatheter repair using the MitraClip system.
Is transcatheter repair with the MitraClip system safe and feasible in patients with heart failure symptoms and severe tricuspid regurgitation?
Observational
Is transcatheter repair with the MitraClip system safe and feasible in patients with heart failure symptoms and severe tricuspid regurgitation?
Answers are grounded in this paper and cite their sources.
Transcatheter edge-to-edge repair using the MitraClip system appears safe and feasible for treating severe tricuspid regurgitation, offering a potential interventional option for symptomatic patients.
BACKGROUND: Current surgical and medical treatment options for severe tricuspid regurgitation (TR) are limited, and additional interventional approaches are required. In the present observational study, the safety and feasibility of transcatheter repair of chronic severe TR with the MitraClip system were evaluated. In addition, the effects on clinical symptoms were assessed. METHODS: Patients with heart failure symptoms and severe TR on optimal medical treatment were treated with the MitraClip system. Safety, defined as periprocedural adverse events such as death, myocardial infarction, stroke, or cardiac tamponade, and feasibility, defined as successful implantation of 1 or more MitraClip devices and reduction of TR by at least 1 grade, were evaluated before discharge and after 30 days. In addition, functional outcome, defined as changes in New York Heart Assocation class and 6-minute walking distance, were assessed. CONCLUSIONS: Transcatheter treatment of TR with the MitraClip system seems to be safe and feasible in this cohort of preselected patients. Initial efficacy analysis showed encouraging reduction of TR, which may potentially result in improved clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Nickenig et al. (2017) conducted an observational in Chronic severe tricuspid regurgitation. Transcatheter edge-to-edge tricuspid repair with the MitraClip system was evaluated on Safety (periprocedural adverse events such as death, MI, stroke, or cardiac tamponade) and feasibility (successful implantation of ≥1 MitraClip devices and reduction of TR by ≥1 grade) (p=0.007). Transcatheter repair of severe tricuspid regurgitation with the MitraClip system appeared safe and feasible at 30 days, showing encouraging TR reduction.
Synapse has enriched 10 related papers. Consider them for comparative context: