The Garmin vivosmart 5 smartwatch demonstrated strong agreement with Holter ECG for heart rate measurement (mean ICC 0.902, mean bias 1.16 bpm) in healthy adults under free-living conditions.
Observational (n=10)
Does a smartwatch with a photoplethysmograph accurately measure heart rate compared to a Holter electrocardiograph in healthy adults under free-living conditions?
A consumer-grade smartwatch with PPG demonstrated strong agreement with Holter ECG for heart rate monitoring in healthy adults during daily activities, despite a slight tendency to underestimate heart rate.
Effect estimate: Mean ICC 0.902
Although consumer-grade smartwatches with a photoplethysmograph (PPG) can measure heart rate, their reliability and validity in healthy participants under free-living conditions remain unclear. Therefore, this study compared the heart rates measured by a smartwatch with PPG and a clinically accepted Holter electrocardiograph in healthy adult participants under completely free-living conditions. Ten participants wore a Holter recorder on their left chest and a Garmin vivosmart 5 on their non-dominant wrist simultaneously for 72-96 h. Averages were calculated every 2 min from the data obtained, and timestamps were used for alignment. Agreement between the measurements taken by the two devices was verified using intraclass correlation and Bland-Altman analyses. Error trends for Garmin vivosmart 5 were examined using linear regression analysis. The overall intraclass correlation coefficient range was 0.819-0.937 (mean: 0.902), indicating strong agreement. The mean bias was 1.16 bpm, and the mean limit of agreement was ±12.4 (7.87-20.6) bpm. Furthermore, the linear regression line intercept was negative for all participants, indicating that Garmin vivosmart 5 tended to underestimate the heart rate; however, the slope was positive and close to 0. Overall, the smartwatch maintained a certain accuracy level under fluctuating heart rates and demonstrated reasonable reliability during sleep or daily activities.
Tan et al. (2026) conducted an observational in Healthy (n=10). Garmin vivosmart 5 smartwatch vs. Holter electrocardiograph was evaluated on Agreement between heart rate measurements (intraclass correlation coefficient) (Mean ICC 0.902). The Garmin vivosmart 5 smartwatch demonstrated strong agreement with Holter ECG for heart rate measurement (mean ICC 0.902, mean bias 1.16 bpm) in healthy adults under free-living conditions.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: