Vascular responsiveness determined by near‐infrared spectroscopy measures of oxygen saturation

View Full Paper
KMKaitlin M. McLayFFFederico Y. FontanaJNJosh P. Nederveen

Key Result

The reperfusion slope of tissue oxygen saturation (StO2) measured by near-infrared spectroscopy significantly correlated with flow-mediated dilation (r = 0.63, P = 0.003) in healthy young men.

Study Design

Type

Cross-Sectional (n=20)

Structured PICO

Does NIRS-derived StO2 reperfusion rate correlate with ultrasound-derived FMD for assessing vascular endothelial function in healthy young men?

P
Population
20 healthy young men, mean age 26 ± 3 years
I
Intervention
Near-infrared spectroscopy (NIRS)-derived measurement of tissue oxygen saturation (StO2) reperfusion rate (slope 2 StO2) after 5 min of distal cuff occlusion of the popliteal artery
C
Comparator
Ultrasound-derived flow-mediated dilation (FMD) after 5 min of distal cuff occlusion
O
Outcome
Correlation between the reperfusion rate of StO2 (slope 2 StO2) and %FMDsurrogate

NIRS-derived slope 2 StO2 significantly correlates with FMD, suggesting it can be used as a non-invasive measure of vascular endothelial function.

Main Result

Effect estimate: r = 0.63

p-value: p=0.003

Abstract

Vascular impairments at the macro- and microcirculatory levels are associated with increased risk for cardiovascular disease. Flow-mediated dilation (FMD) is currently the most widely used method for non-invasive assessment of vascular endothelial function. Recently, near-infrared spectroscopy (NIRS)-derived measures of tissue oxygen saturation (StO2) have been used to characterize the dynamic response of local tissue perfusion to a brief period of ischaemia. The purpose of the present study was to establish correlations between the reperfusion rate of StO2 and FMD. Ultrasound-derived FMD was quantified after 5 min of distal cuff occlusion of the popliteal artery in 20 healthy young men (26 ± 3 years old). Triplicate measurements of end-diastolic arterial diameter were made every 15 s after cuff release, and FMD response was calculated as the greatest percentage change in diameter from baseline (%FMD). The StO2 was measured using NIRS throughout the duration of each test. Two consecutive FMD tests were performed, separated by 30 min of rest, and were averaged for %FMD and StO2. The %FMD was significantly correlated with the reperfusion slope of StO2 after cuff release (slope 2 StO2; r = 0.63, P = 0.003). In conclusion, the present study established a correlation between slope 2 StO2 and %FMD in healthy young men. These data suggest that NIRS-derived slope 2 StO2 can be used as a measure of vascular endothelial function.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

McLay et al. (2015) conducted a cross-sectional in Healthy (n=20). Near-infrared spectroscopy (NIRS) measurement of StO2 reperfusion slope vs. Ultrasound-derived flow-mediated dilation (FMD) was evaluated on Correlation between the reperfusion rate of StO2 and FMD (r = 0.63, p=0.003). The reperfusion slope of tissue oxygen saturation (StO2) measured by near-infrared spectroscopy significantly correlated with flow-mediated dilation (r = 0.63, P = 0.003) in healthy young men.