PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 21, 2009JAMA186 citationsOpen Access

Association of Physician Certification and Outcomes Among Patients Receiving an Implantable Cardioverter-Defibrillator

Jeptha P. Curtis
Jeptha P. CurtisInterventional / Structural Cardiology

Key Points

  • This research aims to examine how the certification of the physician performing ICD implantation affects patient outcomes.
  • Retrospective cohort study using data from the ICD Registry (2006-2007).

Structured PICO

Does ICD implantation by nonelectrophysiologists increase procedural complications and reduce appropriate CRT-D use compared to electrophysiologists in patients receiving an ICD?

P
Population
111,293 patients receiving an implantable cardioverter-defibrillator (ICD) between January 2006 and June 2007, including 35,841 patients who met criteria for CRT-D.
I
Intervention
ICD implantation performed by nonelectrophysiologists (nonelectrophysiologist cardiologists, thoracic surgeons, and other specialists)
C
Comparator
ICD implantation performed by electrophysiologists
O
Outcome
In-hospital procedural complication rates and the proportion of patients meeting criteria for a defibrillator with cardiac resynchronization therapy (CRT-D) who received that devicesafety

ICD implantation by nonelectrophysiologists is associated with a higher risk of procedural complications and a lower likelihood of receiving an indicated CRT-D device compared to implantation by electrophysiologists.

Abstract

CONTEXT: Allowing nonelectrophysiologists to perform implantable cardioverter-defibrillator (ICD) procedures is controversial. However, it is not known whether outcomes of ICD implantation vary by physician specialty. OBJECTIVE: To determine the association of implanting physician certification with outcomes following ICD implantation. DESIGN, SETTING, AND PATIENTS: Retrospective cohort study using cases submitted to the ICD Registry performed between January 2006 and June 2007. Patients were grouped by the certification status of the implanting physician into mutually exclusive categories: electrophysiologists, nonelectrophysiologist cardiologists, thoracic surgeons, and other specialists. Hierarchical logistic regression models were developed to determine the independent association of physician certification with outcomes. MAIN OUTCOME MEASURES: In-hospital procedural complication rates and the proportion of patients meeting criteria for a defibrillator with cardiac resynchronization therapy (CRT-D) who received that device. RESULTS: Of 111, 293 ICD implantations included in the analysis, 78, 857 (70. 9%) were performed by electrophysiologists, 24, 399 (21. 9%) by nonelectrophysiologist cardiologists, 1862 (1. 7%) by thoracic surgeons, and 6175 (5. 5%) by other specialists. Compared with patients whose ICD was implanted by electrophysiologists, patients whose ICD was implanted by either nonelectrophysiologist cardiologists or thoracic surgeons were at increased risk of complications in both unadjusted (electrophysiologists, 3. 5% 2743/78, 857; nonelectrophysiologist cardiologists, 4. 0% 970/24, 399; thoracic surgeons, 5. 8% 108/1862; P <. 001) and adjusted analyses (relative risk RR for nonelectrophysiologist cardiologists, 1. 11 95% confidence interval CI, 1. 01-1. 21; RR for thoracic surgeons, 1. 44 95% CI, 1. 15-1. 79). Among 35, 841 patients who met criteria for CRT-D, those whose ICD was implanted by physicians other than electrophysiologists were significantly less likely to receive a CRT-D device compared with patients whose ICD was implanted by an electrophysiologist in both unadjusted (electrophysiologists, 83. 1% 21 303/25, 635; nonelectrophysiologist cardiologists, 75. 8% 5950/7849; thoracic surgeons, 57. 8% 269/465; other specialists, 74. 8% 1416/1892; P <. 001) and adjusted analyses (RR for nonelectrophysiologist cardiologists, 0. 93 95% CI, 0. 91-0. 95; RR for thoracic surgeons, 0. 81 95% CI, 0. 74-0. 88; RR for other specialists, 0. 97 95% CI, 0. 94-0. 99). CONCLUSIONS: In this registry, nonelectrophysiologists implanted 29% of ICDs. Overall, implantations by a nonelectrophysiologist were associated with a higher risk of procedural complications and lower likelihood of receiving a CRT-D device when indicated compared with patients whose ICD was implanted by an electrophysiologist.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Jeptha P. Curtis (2009) studied this question.