PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 1, 2001Journal of Hypertension263 citations

Electronic compliance monitoring in resistant hypertension: the basis for rational therapeutic decisions

View Full Paper
MBMichel BurnierMSMarie Paule SchneiderACArnaud Chioléro

Key Result

Electronic monitoring of drug compliance in patients with resistant hypertension significantly improved blood pressure at 2 months (from 156/106 to 145/97 mmHg, P<0.01).

Study Design

Type

Observational (n=41)

Structured PICO

Does electronic monitoring of drug compliance improve blood pressure control in patients with resistant hypertension?

P
Population
41 hypertensive patients resistant to a three-drug regimen, with an average baseline blood pressure of 156/106 +/- 23/11 mmHg.
I
Intervention
Electronic monitoring of drug compliance for 2 months (with presently prescribed drugs provided in electronic monitors without treatment change), followed by an optional 2-month extension with treatment adaptation.
O
Outcome
Change in blood pressure at 2 months.surrogate

Electronic monitoring of drug compliance significantly improves blood pressure in patients with resistant hypertension by unmasking non-compliance and guiding therapeutic decisions.

Main Result

p-value: p=< 0.01

Abstract

OBJECTIVE: Incomplete compliance is one of several possible causes of uncontrolled hypertension. Yet, non-compliance remains largely unrecognized and is falsely interpreted as treatment resistance, because it is difficult to confirm or exclude objectively. The goal of this study was to evaluate the potential benefits of electronic monitoring of drug compliance in the management of patients with resistant hypertension. METHODS: Forty-one hypertensive patients resistant to a three-drug regimen (average blood pressure 156/ 106 +/- 23/11 mmHg, mean +/- SD) were studied prospectively. They were informed that for the next 2 months, their presently prescribed drugs would be provided in electronic monitors, without any change in treatment, so as to provide the treating physician with a measure of their compliance. Thereafter, patients were offered the possibility of prolonging the monitoring of compliance for another 2 month period, during which treatment was adapted if necessary. RESULTS: Monitoring of compliance alone was associated with a significant improvement of blood pressure at 2 months (145/97 +/- 20/15 mmHg, P < 0.01). During monitoring, blood pressure was normalized (systolic < 140 mmHg or diastolic < 90 mmHg) in one-third of the patients and insufficient compliance was unmasked in another 20%. When analysed according to tertiles of compliance, patients with the lowest compliance exhibited significantly higher achieved diastolic blood pressures (P = 0.04). In 30 patients, compliance was monitored up to 4 months and drug therapy was adapted whenever necessary. In these patients, a further significant decrease in blood pressure was obtained (from 150/100 +/- 18/15 to 143/94 +/- 22/11 mmHg, P = 0.04/0.02). CONCLUSIONS: These results suggest that objective monitoring of compliance using electronic devices may be a useful step in the management of patients with refractory hypertension, as it enables physicians to take rational decisions based on reliable and objective data of drug compliance and hence to improve blood pressure control.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Burnier et al. (2001) conducted an observational in Resistant hypertension (n=41). Electronic monitoring of drug compliance vs. Baseline was evaluated on Blood pressure at 2 months (p=< 0.01). Electronic monitoring of drug compliance in patients with resistant hypertension significantly improved blood pressure at 2 months (from 156/106 to 145/97 mmHg, P<0.01).

synapsesocial.com/papers/6a156e4ea2352da347826d0bhttps://doi.org/10.1097/00004872-200102000-00022
Ask AI
Helpful
Bookmark
Share
View Full Paper