March 1, 1998AJP Heart and Circulatory Physiology553 citations

Measurement of heart rate and Q-T interval in the conscious mouse

View Full Paper
GMGary F. MitchellAJAndreas JeronGKGideon Koren

Key Points

  • To evaluate heart rate and Q-T intervals in conscious mice using telemetry, and relate them to cardiac function.
  • Developed a telemetry system for electrocardiogram recording in conscious mice.

Structured PICO

P
Population
6 FVB mice (3 male, 3 female)
I
Intervention
Implantable telemetry system for ECG recording and analysis
O
Outcome
Measurement of R-R and Q-T intervalssurrogate

An implantable telemetry system in conscious mice provides a sensitive model with low variability for detecting changes in the Q-T interval, avoiding the confounding effects of anesthesia.

Abstract

Transgenic mouse models provided a powerful tool to evaluate the physiological significance of altered quantities or characteristics of specific gene products, such as cardiac ion channels. We have developed a system to record and analyze changes in the electrocardiogram in the mouse using an implantable telemetry system. The R-R and Q-T intervals were measured on individual beats and on signal-averaged complexes derived from 1, 2, or 4 s of contiguous data each hour during a 24-h period in three male and three female FVB mice. Duration of averaging had minimal effect on the measured Q-T. The Q-T interval was shown to be related to the square root of the R-R interval, and an appropriate formula for a rate-corrected Q-T interval (Q-Tc) was derived. Ketamine anesthesia was shown to markedly increase duration and variability in R-R, Q-T, and Q-Tc intervals. In conscious animals, variability in Q-T was low across animals and over time, suggesting that this should be a sensitive model for detection of changes in the Q-T interval in transgenic mice with ion channel defects.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Mitchell et al. (1998) studied this question.

synapsesocial.com/papers/6a1785ea7afe20c06351e044https://doi.org/10.1152/ajpheart.1998.274.3.h747
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Measurement and interpretation of electrocardiographic QT intervals in murine hearts2014
  2. 2Physiology and analysis of the electrocardiographic <scp>T</scp> wave in mice2013 · 70 citations
  3. 3Model-based estimation of QT intervals of mouse fetal electrocardiogram2022
  4. 4Prolonged QT intervals in mice with cardiomyocyte‐specific deficiency of the molecular clock2021 · 28 citations
  5. 5In Vivo Cardiac Electrophysiology Studies in the Mouse1996 · 228 citations