PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 24, 2004AJP Heart and Circulatory Physiology25 citations

Time-varying effective mitral valve area: prediction and validation using cardiac MRI and Doppler echocardiography in normal subjects

View Full Paper
ABAndrew W. BowmanPFPaul FrihaufSKSándor J. Kovács

Structured PICO

Does the effective mitral valve area remain constant throughout early rapid left ventricular filling in normal subjects?

P
Population
10 normal subjects
I
Intervention
Synchronized cardiac magnetic resonance imaging (MRI) and contemporaneous Doppler echocardiography
O
Outcome
Effective mitral valve area (EMVA) variation as a function of time during early diastolesurrogate

The effective mitral valve area is not constant during early rapid left ventricular filling, which affects the physiological interpretation of the Doppler E wave velocity-time integral.

Abstract

Precise knowledge of the volume and rate of early rapid left ventricular (LV) filling elucidates kinematic aspects of diastolic physiology. The Doppler E wave velocity-time integral (VTI) is conventionally used as the estimate of early, rapid-filling volume; however, this implicitly requires the assumption of a constant effective mitral valve area (EMVA). We sought to evaluate whether the EMVA is truly constant throughout early, rapid filling in 10 normal subjects using cardiac magnetic resonance imaging (MRI) and contemporaneous Doppler echocardiography, which were synchronized via ECG. LV volume measurements as a function of time were obtained via MRI, and transmitral flow values were measured via Doppler echocardiography. The synchronized data were used to predict EMVA as a function of time during early diastole. Validation involved EMVA determination using 1) the short-axis echocardiographic images near the mitral valve leaflet tips, 2) the distance between leaflet tips in the echocardiographic parasternal long-axis view, and 3) the distance between leaflet tips from the MRI LV outflow tract view. Predicted EMVA values varied substantially during early rapid filling, and observed EMVA values agreed well with predictions. We conclude that the EMVA is not constant, and its variation causes LV volume to increase faster than is reflected by the VTI. These results reveal the mechanism of early rapid volumetric increase and directly affect the significance and physiological interpretation of the VTI of the Doppler E wave. Application to subjects in selected pathophysiological subsets is in progress.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bowman et al. (2004) studied this question.

synapsesocial.com/papers/6a1c9ea2a0feb26cffe78e0bhttps://doi.org/10.1152/ajpheart.00269.2004