  • The study investigates daylighting conditions in Kaduna libraries, aiming to enhance comfort and energy efficiency.
  • Analyzed three library case studies using climate-based daylight modeling and field measurements.
  • Employed Velux Daylight Visualizer and Revit® to evaluate illuminance and glare.
  • Conducted user surveys to assess lighting comfort preferences.
  • Uneven daylight distribution and excessive glare near windows were observed.
  • Illuminance levels dropped below 300 lux in core areas despite 662.91 lux near windows.
  • Survey revealed 74% of users preferred better-lit seating areas, leading to high artificial lighting reliance.

Abstract

p strongPurpose:/strong This study investigates the existing daylighting conditions in selected library spaces in Kaduna State, Nigeria, recognising that abundant natural light in the tropical wet-dry climate is underutilised. It aims to assess the visual comfort, light distribution, and energy efficiency challenges associated with traditional daylighting design approaches. /p p strongDesign/methodology/approach:/strong The study analysed three library case studies using climate-based daylight modelling and field measurements. Tools such as Velux Daylight Visualizer and Revit® were employed to evaluate illuminance levels and glare conditions. User surveys were also conducted to understand seating preferences regarding lighting comfort. /p p strongFindings:/strong Results revealed uneven daylight distribution, excessive glare near windows, and insufficient illumination at core reading areas (often lt;300 lux). Average illuminance near windows reached 662.91 lux, but dropped significantly deeper into spaces. This shortfall leads to reliance on artificial lighting, contributing 20–30% to building energy loads. Survey feedback showed that 74% of users preferred well-lit seating areas. /p p strongResearch limitations/Implications:/strong The study is limited to selected libraries within Kaduna State and focuses primarily on side-lighting design, which may not reflect design variations across Nigeria. Simulation accuracy, although validated, may not capture all real-time conditions. Future research should explore the long-term performance of enhanced daylighting strategies and broader user behaviour. /p p strongPractical implications:/strong Findings highlight the need to improve daylighting performance to enhance visual comfort, reduce operational costs, and mitigate reliance on artificial lighting in regions with unstable electricity. Introducing top-lighting strategies, including light pipes, is recommended to extend daylight penetration and improve energy efficiency. /p p strongOriginality/value –/strong This research provides a foundational re-analysis of daylighting in library spaces within the tropical Nigerian context. It offers evidence-based guidance for redesigning educational buildings to improve sustainability, wellbeing, and learning environments, addressing a critical gap in regional architectural practice. /p