PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 23, 20241 citations

Assessment of Hemodialysis Adequacy by Online Clearance Monitoring.

View Full Paper
MAMurukeshan AnandiMMMuniappan MuthamizhSISuyampirakasam Ilango

Key Result

Online clearance monitoring (OCM) spKt/V showed positive correlations with Daugirdas spKt/V and Urea Reduction Ratio (URR) in assessing maintenance hemodialysis adequacy.

Study Design

Type

Cross-Sectional (n=100)

Multicenter

No

Structured PICO

Does online clearance monitoring (OCM) correlate with traditional methods (URR and Daugirdas spKt/V) for assessing hemodialysis adequacy in maintenance hemodialysis patients?

P
Population
100 participants undergoing maintenance hemodialysis therapy evaluated over 200 sessions.
E
Exposure
Online clearance monitoring (OCM) spKt/V
C
Comparator
Urea Reduction Ratio (URR) and Daugirdas spKt/V
O
Outcome
Correlation between OCM spKt/V, URR, and Daugirdas spKt/Vsurrogate

Online clearance monitoring is a viable alternative to traditional blood sampling methods for assessing hemodialysis adequacy.

Abstract

Measuring the uremic solute clearance is an important factor in analyzing the adequacy of maintenance hemodialysis (MHD) therapy. Conventionally hemodialysis (HD) adequacy was measured by urea removal through the Daugirdas single pool kt/V (spKt/V) formula. We aimed in our study to correlate online clearance monitoring (OCM) spKt/V to the Urea Reduction Ratio (URR) and Daugirdas spKt/V in maintenance hemodialysis patients. This single-center cross-sectional study, conducted at the hemodialysis unit in the nephrology department of SRM Medical College Hospital and Research Center, involved 100 participants undergoing maintenance hemodialysis (MHD) therapy for 200 sessions. The OCM with URR and Daugirdas spKt/V values were obtained from each session and the results were analyzed using SPSS software with p <0.05 significance. In the results, we found that the OCM spKt/V, Daugirdas spKt/V, and URR showed positive correlations. These results emphasize that OCM can be an alternative method to assess dialysis adequacy for every session without the need for repeated blood sampling.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Anandi et al. (2024) conducted a cross-sectional in Maintenance hemodialysis (n=100). Online clearance monitoring (OCM) vs. Daugirdas spKt/V and Urea Reduction Ratio (URR) was evaluated on Correlation of OCM spKt/V to URR and Daugirdas spKt/V. Online clearance monitoring (OCM) spKt/V showed positive correlations with Daugirdas spKt/V and Urea Reduction Ratio (URR) in assessing maintenance hemodialysis adequacy.

synapsesocial.com/papers/6a5eb2e40b9d991ba0aef54bhttps://doi.org/10.69097/41-06-2024-11
Ask AI
Helpful
Bookmark
Share
View Full Paper