April 13, 2005New England Journal of Medicine48 citations

Resynchronizing Ventricular Contraction in Heart Failure

View Full Paper
JJJohn A. Jarcho

Key Result

Dyssynchronous electrical activation in congestive heart failure results in mechanically inefficient contraction and altered regional myocardial blood flow.

PICO

P
Population
Congestive heart failure

Abstract

One quarter to one third of patients with congestive heart failure have some form of intraventricular conduction abnormality that is manifested as an increased QRS duration on the electrocardiogram.1,2 The most common pattern is left bundle-branch block. In patients with left bundle-branch block, electrical activation of the lateral aspect of the left ventricle can be substantially delayed in relation to that of the right ventricle and interventricular septum. Dyssynchronous electrical activation results in dyssynchronous contraction, which is mechanically inefficient. Regional myocardial workload is distributed unequally, and regional myocardial blood flow and metabolism may be altered. As a result, the . . .

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

John A. Jarcho (2005) conducted an editorial in Congestive heart failure. Dyssynchronous electrical activation in congestive heart failure results in mechanically inefficient contraction and altered regional myocardial blood flow.